文献速递心血管介入技术与安全DSA

图像增强能否在保持冠状动脉造影所需主观诊断图像质量的同时降低辐射剂量?

Can image enhancement allow radiation dose to be reduced whilst maintaining the perceived diagnostic image quality required for coronary angiography?
PubMed 文献 · Br J Radiol · 2017-01-26

研究向5例经皮冠状动脉介入治疗(PCI)患者的血管造影图像中逐步加入噪声以模拟10%–89%的剂量降低,16名观察者分别对无图像处理及两种现代图像处理算法下的图像质量进行评分。结果显示,最先进和上一代图像处理算法分别可在剂量降低24.9%和15.6%时保持与未增强图像等效的主观质量,最先进算法较上一代算法可额外降低10.3%的剂量。

要点

  • 现代图像增强可在不损失主观图像质量的前提下实现统计学显著的辐射剂量降低。
  • 最先进图像处理算法在较低剂量下保持图像质量的效果优于上一代算法。
  • 观察者评分显示,最先进和上一代算法分别支持24.9%和15.6%的剂量降低。

核心结论

  • 使用现代图像增强可在不损失主观图像质量的情况下实现统计学显著的剂量降低,且最新处理算法在较低剂量下保持图像质量更为有效。

研究设计与样本

  • 研究向5例PCI患者血管造影图像中逐步加入噪声,模拟10%–89%的剂量降低,16名有相关经验的观察者在无图像处理及两种现代图像处理算法下对图像质量进行评分,采用有序回归(含随机效应)和delta法量化等效图像质量评分下可实现的剂量降低。

诊断标准与关键数值

  • 最先进图像处理算法处理的图像在剂量降低24.9%时,观察者评分与未增强图像质量等效。
  • 上一代图像处理算法处理的图像在剂量降低15.6%时,观察者评分与未增强图像质量等效。
  • 最先进图像处理算法相对上一代算法可额外降低10.3%的剂量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The aim of this research was to quantify the reduction in radiation dose facilitated by image processing alone for percutaneous coronary intervention (PCI) patient angiograms, without reducing the perceived image quality required to confidently make a diagnosis.

METHODS: Incremental amounts of image noise were added to five PCI angiograms, simulating the angiogram as having been acquired at corresponding lower dose levels (10-89% dose reduction). 16 observers with relevant experience scored the image quality of these angiograms in 3 states-with no image processing and with 2 different modern image processing algorithms applied. These algorithms are used on state-of-the-art and previous generation cardiac interventional X-ray systems. Ordinal regression allowing for random effects and the delta method were used to quantify the dose reduction possible by the processing algorithms, for equivalent image quality scores.

RESULTS: Observers rated the quality of the images processed with the state-of-the-art and previous generation image processing with a 24.9% and 15.6% dose reduction, respectively, as equivalent in quality to the unenhanced images. The dose reduction facilitated by the state-of-the-art image processing relative to previous generation processing was 10.3%.

CONCLUSION: Results demonstrate that statistically significant dose reduction can be facilitated with no loss in perceived image quality using modern image enhancement; the most recent processing algorithm was more effective in preserving image quality at lower doses. Advances in knowledge: Image enhancement was shown to maintain perceived image quality in coronary angiography at a reduced level of radiation dose using computer software to produce synthetic images from real angiograms simulating a reduction in dose.