整合CT心肌灌注与CT-FFR在冠状动脉疾病检查中的应用
研究纳入2个中心的74例患者共142支血管,评估动态CT心肌灌注成像与CT血管造影血流储备分数对功能性冠状动脉疾病的诊断准确性。CT MPI敏感度73%、特异度68%、准确率70%,CTA FFR分别为82%、60%、70%;两者整合后AUC从0.78提高到0.85(p<0.05)。
要点
- CT MPI与CTA FFR对功能性显著冠脉疾病的诊断准确率相当(均为70%)。
- 两者整合后诊断准确率79%,AUC从0.78提高到0.85(p<0.05)。
- 阶梯式方法(CTA FFR中间结果时选做CT MPI)准确率77%,可使近半数人群免于CT MPI检查。
核心结论
- CT MPI与CTA FFR均能识别功能性显著冠状动脉疾病,准确率相当;联合两种技术可提高诊断性能,以CTA FFR中间结果时选做CT MPI的阶梯式方法亦提高诊断性能,同时使近半数人群免于CT MPI检查。
研究设计与样本
- 来自2个机构的74例患者(62例男性,平均年龄61岁)计划行有创血管造影并在142支血管行有创FFR测量,接受CTA成像及腺苷血管扩张下的动态CT MPI。计算患者特异性心肌血流量指数并对远端心肌全局左心室血流归一化;CTA FFR使用现场临床医生操作的应用计算;采用二元回归创建结合CT MPI与CTA FFR的单一功能CT变量;模拟CTA FFR阶梯式诊断流程并选择性使用CT MPI;以有创FFR阈值0.80为参考,采用C统计量评估诊断性能。
诊断标准与关键数值
- 以有创FFR阈值0.80为参考:CT MPI敏感度73%(95%CI 61%–86%)、特异度68%(95%CI 56%–80%)、准确率70%(95%CI 62%–79%);CTA FFR敏感度82%(95%CI 72%–92%)、特异度60%(95%CI 48%–72%)、准确率70%(95%CI 63%–80%);CT MPI整合CTA FFR准确率79%(95%CI 71%–87%),AUC从0.78提高到0.85(p<0.05);阶梯式方法准确率77%。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to investigate the individual and combined accuracy of dynamic computed tomography (CT) myocardial perfusion imaging (MPI) and computed tomography angiography (CTA) fractional flow reserve (FFR) for the identification of functionally relevant coronary artery disease (CAD).
BACKGROUND: Coronary CTA has become an established diagnostic test for ruling out CAD, but it does not allow interpretation of the hemodynamic severity of stenotic lesions. Two recently introduced functional CT techniques are dynamic MPI and CTA FFR using computational fluid dynamics.
METHODS: From 2 institutions, 74 patients (n = 62 men, mean age 61 years) planned for invasive angiography with invasive FFR measurement in 142 vessels underwent CTA imaging and dynamic CT MPI during adenosine vasodilation. A patient-specific myocardial blood flow index was calculated, normalized to remote myocardial global left ventricular blood flow. CTA FFR was computed using an on-site, clinician-operated application. Using binary regression, a single functional CT variable was created combining both CT MPI and CTA FFR. Finally, stepwise diagnostic work-up of CTA FFR with selective use of CT MPI was simulated. The diagnostic performance of CT MPI, CTA FFR, and CT MPI integrated with CTA FFR was evaluated using C statistics with invasive FFR, with a threshold of 0.80 as a reference.
RESULTS: Sensitivity, specificity, and accuracy were 73% (95% confidence interval [CI]: 61% to 86%), 68% (95% CI: 56% to 80%), and 70% (95% CI: 62% to 79%) for CT MPI and 82% (95% CI: 72% to 92%), 60% (95% CI: 48% to 72%), and 70% (63% to 80%) for CTA FFR. For CT MPI integrated with CTA FFR, diagnostic accuracy was 79% (95% CI: 71% to 87%), with improvement of the area under the curve from 0.78 to 0.85 (p < 0.05). Accuracy of the stepwise approach was 77%.
CONCLUSIONS: CT MPI and CTA FFR both identify functionally significant CAD, with comparable accuracy. Diagnostic performance can be improved by combining the techniques. A stepwise approach, reserving CT MPI for intermediate CTA FFR results, also improves diagnostic performance while omitting nearly one-half of the population from CT MPI examinations.
引用
- Coenen A, Rossi A, Lubbers MM, et al. Integrating CT Myocardial Perfusion and CT-FFR in the Work-Up of Coronary Artery Disease. JACC Cardiovasc Imaging. 2017. PMID: 28109933. doi:10.1016/j.jcmg.2016.09.028