文献速递胸部技术与安全USCT

高分辨率经胸超声评估呼吸困难患者胸膜线的CT对照观察性研究

High-Resolution Transthoracic Ultrasonography for Assessment of Pleural Lines in Patients With Dyspnea With CT Comparison: An Observational Study.
PubMed 文献 · J Ultrasound Med · 2017-01-27

本研究对116例急诊呼吸困难患者行高分辨率经胸超声,以同部位高分辨率CT为金标准,评估胸膜线异常与B线的相关性及诊断效能。68.1%患者存在胸膜线改变,共分为四种类型,分别对应CT上的磨玻璃影、肺实质浸润、磨玻璃合并不规则网状影及小叶间隔增厚,波浪状胸膜线提示胸膜下肺气肿。

要点

  • 胸膜线略粗糙伴融合B线对应CT磨玻璃影。
  • 胸膜线不规则中断伴融合B线对应肺实质浸润。
  • 胸膜线毛糙伴融合B线对应磨玻璃合并不规则网状影。

核心结论

  • 高分辨率经胸超声可通过识别胸膜线异常和B线辅助肺部病变的初步评估,这些表现与CT相关,可能为急诊呼吸困难患者的评估增加诊断价值。

研究设计与样本

  • 观察性研究,纳入116例急诊呼吸困难患者,采用线阵探头行经胸超声,以同部位高分辨率CT为金标准进行对照。

关键影像表现/征象

  • 胸膜线略粗糙伴融合B线,对应CT磨玻璃影。
  • 胸膜线不规则且中断伴融合B线,对应肺实质浸润。
  • 胸膜线毛糙伴融合B线,对应磨玻璃影合并不规则网状影。
  • 胸膜线毛糙伴散在B线,对应不规则增厚的小叶间隔。
  • 波浪状胸膜线提示胸膜下肺气肿;31例(26.7%)存在一种以上异常胸膜线。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Detection of B-line in dyspneic patients is often accompanied by abnormal changes of pleural line on transthoracic ultrasonography (TUS). The aim of the study was to evaluate the relevance and diagnostic performance of pleural line abnormalities and B-lines detected on high-resolution TUS against the computed tomography (CT) findings.

METHODS: Transthoracic ultrasonography was performed in patients admitted to the emergency department with dyspnea. The pleural line and accompanying B-line were assessed using a linear transducer. The TUS findings were assessed against the corresponding high-resolution CT findings in the same location, which were considered to be the gold standard.

RESULTS: Out of a total of 116 patients, 68.1% had changes of the pleural line on TUS. The characteristic changes of the pleural line were classified into four types: slightly rough pleural line with confluent B-lines on TUS corresponded with CT findings of ground-glass opacity; irregular and interrupted pleural line with confluent B-lines corresponded with parenchymal infiltration; fringed pleural line with confluent B-lines corresponded with superimposed ground-glass and irregular reticular opacities; and fringed pleural line with scattered B-lines corresponded with irregularly thickened interlobular septa. Wavy pleural line indicated subpleural emphysema. The coexistence of more than one abnormal pleural line was also found in 31 cases (26.7%).

CONCLUSIONS: High-resolution TUS may help in the initial assessment of lung pathology by its ability to identify pleural line abnormalities and B-lines that are shown to be associated with CT, which could add diagnostic value in the emergency evaluation of dyspneic patients.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Li H, Li YD, Zhu WW, et al. High-Resolution Transthoracic Ultrasonography for Assessment of Pleural Lines in Patients With Dyspnea With CT Comparison: An Observational Study. J Ultrasound Med. 2017. PMID: 28127786. doi:10.7863/ultra.16.04030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。