双能CT虚拟去钙技术检测椎体骨折患者骨髓水肿:单源容积CT扫描仪的前瞻性可行性研究

Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: A prospective feasibility study on a single- source volume CT scanner.
PubMed 文献 · Eur J Radiol · 2016-12-12

前瞻性纳入9例胸椎或腰椎压缩性骨折患者,行单源320排DECT与1.5T MRI,以MRI为参考标准评估虚拟去钙(VNC)图像检测骨髓水肿的可靠性。14个目标椎体中MRI显示8个骨髓水肿,DECT检出7个,无假阳性,敏感度0.88(0.75-1.0)、特异度1.0(0.81-1.0);DECT读者间一致性(κ=0.63-0.89)低于MRI(κ=0.9-1.0)。作者结论:单源DECT检测骨髓水肿可行,但VNC图像质量需改进以提高读者间一致性。

要点

  • VNC图像检测椎体骨髓水肿无假阳性,特异度达1.0(0.81-1.0),敏感度0.88(0.75-1.0)。
  • DECT读者间一致性κ=0.63-0.89,低于MRI的κ=0.9-1.0,提示VNC图像判读一致性有待提高。
  • VNC图像椎体间比值与STIR信号强度强相关(r=0.87),与T1呈负相关(-0.89)。

核心结论

  • 单源DECT检测椎体压缩性骨折骨髓水肿可行,具有相当高的敏感度和特异度;但VNC重建图像质量需改进以获得更好的读者间一致性。

研究设计与样本

  • 前瞻性可行性研究(pilot study),纳入9例X线显示胸椎或腰椎压缩性骨折的患者,采用320排单源DECT和1.5T MRI,以MRI为参考标准;由三名盲法读者独立评分,仅分析X线有高度丢失的目标椎体,两名读者一致判定为阳性。

关键影像表现/征象

  • VNC图像上骨髓水肿表现为椎体密度改变,其椎体间比值与STIR信号强度强相关(r=0.87),与T1信号呈负相关(-0.89)。
  • VNC图像的信噪比(SNR)为0.2±0.2,STIR为16.7±7.3;对比噪声比(CNR)VNC为0.2±0.3,STIR为7.1±6.3,VNC均较低。
  • 14个X线高度丢失的目标椎体中,MRI显示8个有骨髓水肿,DECT检出7个,无假阳性VNC图像。

诊断标准与关键数值

  • 以MRI为参考标准,DECT检测骨髓水肿的敏感度为0.88(0.75-1.0,所有读者范围),特异度为1.0(0.81-1.0)。
  • 读者间一致性:DECT的Cohen's κ=0.63-0.89,MRI的κ=0.9-1.0。
  • 阳性判定标准:两名读者一致认为存在骨髓水肿的椎体计为阳性。

临床应用与阅片要点

  • VNC图像可作为检测椎体压缩性骨折伴骨髓水肿的辅助手段,无假阳性发现。
  • VNC图像信噪比和对比噪声比均较低(SNR 0.2±0.2,CNR 0.2±0.3),判读时需注意图像质量对读者间一致性的影响。
  • 作者认为DECT未来可能加速椎体压缩性骨折患者的诊断流程并减少额外MRI检查的数量。

局限性

  • 本研究为初步可行性研究(pilot study),样本量小(9例患者,14个目标椎体)。
  • VNC重建图像质量需改进以达到更好的读者间一致性。
  • DECT读者间一致性(κ=0.63-0.89)低于MRI(κ=0.9-1.0)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Dual-energy computed tomography (DECT) is a recent development for detecting bone marrow edema (BME) in patients with vertebral compression fractures. The aim of this pilot study was to determine the reliability of single-source DECT in detecting vertebral BME using magnetic resonance imaging (MRI) as standard of reference.

MATERIALS AND METHODS: Nine patients with radiographic thoracic or lumbar vertebral compression fractures underwent both, DECT on a 320-row single-source scanner and 1.5T MRI. Virtual non-calcium (VNC) images were reconstructed from the DECT volume datasets. Three blinded readers independently scored images for the presence of BME. Only vertebrae with loss of height in radiography (target vertebrae) were included in the analysis. A vertebra was counted as positive if two readers agreed on the presence of BME. Cohen's kappa was calculated for interrater comparison. Intervertebral ratios of target and the reference vertebra were compared for CT attenuation and MR signal intensity in a reference vertebra using Spearman correlation. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated.

RESULTS: Fourteen target vertebrae with a radiographic height loss were identified; eight of them showed BME on MRI, while DECT identified BME in 7 instances. There were no false positive virtual non-calcium images, resulting in a sensitivity of 0.88 (0.75-1.0 among all readers) and specificity of 1.0 (0.81-1.0). Interrater agreement was inferior for DECT (κ=0.63-0.89) compared to MRI (κ=0.9-1.0). Intervertebral ratio in VNC images strongly correlated with short-tau inversion recovery (r=0.87) and inversely with T1 (-0.89). SNR (0.2+/- 0.2 in VNC and 16.7+/- 7.3 in STIR) and CNR (0.2+/- 0.3 and 7.1+/- 6.3) values were inferior in VNC.

CONCLUSIONS: Detecting BME with single-source DECT is feasible and allows detection of vertebral compression fractures with reasonably high sensitivity and specificity. However, image quality of VNC reconstructions has to be improved to achieve better interrater agreement. Nonetheless, DECT might accelerate the diagnostic work-flow in patients with vertebral compression fractures in the future and reduce the number of additional MRI examinations.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Diekhoff T, Hermann KG, Pumberger M, et al. Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: A prospective feasibility study on a single- source volume CT scanner. Eur J Radiol. 2016. PMID: 28065376. doi:10.1016/j.ejrad.2016.12.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。