超低剂量CT在胸部X线等效剂量下检测肺结节的准确性:一项前瞻性个体内对比研究

Ultralow dose CT for pulmonary nodule detection with chest x-ray equivalent dose - a prospective intra-individual comparative study.
PubMed 文献 · Eur Radiol · 2017-01-16

前瞻性纳入202例临床需行胸部CT的患者,标准剂量CT(1.8±0.7 mSv)作为参考标准,超低剂量CT(0.13±0.01 mSv,100 kV锡滤过)检测肺结节的总体敏感度为91%;亚实性结节敏感度较低(77.5%);结节类型、大小和患者BMI是敏感度的独立预测因素(p<0.001)。

要点

  • 超低剂量CT(0.13 mSv)对肺结节的总体敏感度为91%。
  • 亚实性结节在超低剂量CT上的敏感度为77.5%。
  • 结节类型、大小和患者BMI是敏感度的独立预测因素(p<0.001)。

核心结论

  • 100 kV锡滤过超低剂量胸部CT在相当于胸部X线平片的曝光剂量下,对肺结节检测具有高敏感度;亚实性结节敏感度较低(77.5%);超低剂量CT似乎可用于肺癌筛查。

研究设计与样本

  • 前瞻性个体内对比研究,连续纳入202例临床需行胸部CT的患者,标准剂量CT(1.8±0.7 mSv)由两名委员会认证放射科医师共识阅片作为参考标准,超低剂量CT(0.13±0.01 mSv,100 kV,锡滤过)由两名放射科医师评估。

诊断标准与关键数值

  • 超低剂量CT检测肺结节的总体敏感度为91%。
  • 超低剂量CT检测亚实性结节的敏感度为77.5%。
  • 参考标准共发现425个结节,平均直径3.7±2.9 mm。
  • 结节类型、大小和患者BMI是敏感度的独立预测因素(p<0.001)。
  • 标准剂量CT有效剂量为1.8±0.7 mSv,超低剂量CT为0.13±0.01 mSv。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To prospectively evaluate the accuracy of ultralow radiation dose CT of the chest with tin filtration at 100 kV for pulmonary nodule detection.

MATERIALS AND METHODS: 202 consecutive patients undergoing clinically indicated chest CT (standard dose, 1.8 ± 0.7 mSv) were prospectively included and additionally scanned with an ultralow dose protocol (0.13 ± 0.01 mSv). Standard dose CT was read in consensus by two board-certified radiologists to determine the presence of lung nodules and served as standard of reference (SOR). Two radiologists assessed the presence of lung nodules and their locations on ultralow dose CT. Sensitivity and specificity of the ultralow dose protocol was compared against the SOR, including subgroup analyses of different nodule sizes and types. A mixed effects logistic regression was used to test for independent predictors for sensitivity of pulmonary nodule detection.

RESULTS: 425 nodules (mean diameter 3.7 ± 2.9 mm) were found on SOR. Overall sensitivity for nodule detection by ultralow dose CT was 91%. In multivariate analysis, nodule type, size and patients BMI were independent predictors for sensitivity (p < 0.001).

CONCLUSIONS: Ultralow dose chest CT at 100 kV with spectral shaping enables a high sensitivity for the detection of pulmonary nodules at exposure levels comparable to plain film chest X-ray.

KEYPOINTS: • 91% of all lung nodules were detected with ultralow dose CT • Sensitivity for subsolid nodule detection is lower in ultralow dose CT (77.5%) • The mean effective radiation dose in 202 patients was 0.13 mSv • Ultralow dose CT seems to be feasible for lung cancer screening.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Messerli M, Kluckert T, Knitel M, et al. Ultralow dose CT for pulmonary nodule detection with chest x-ray equivalent dose - a prospective intra-individual comparative study. Eur Radiol. 2017. PMID: 28093625. doi:10.1007/s00330-017-4739-6