文献速递妇产影像儿科影像US

三维超声测量脐静脉偏移角预测左侧先天性膈疝胎儿肝脏疝入

Three-dimensional assessment of umbilical vein deviation angle for prediction of liver herniation in left-sided congenital diaphragmatic hernia.
PubMed 文献 · Ultrasound Obstet Gynecol · 2017-12-27

本研究在22例左侧先天性膈疝胎儿和88例正常对照中,利用三维超声离线测量脐静脉偏移角(UVDA),发现膈疝组UVDA显著高于对照组,且肝脏疝入组显著高于未疝入组;ROC曲线分析显示UVDA预测肝脏疝入的AUC为0.94,最佳截断值15.2°时敏感度89%、特异度100%。作者认为该指标似乎能准确预测左侧先天性膈疝胎儿的肝脏疝入。

要点

  • UVDA在左侧先天性膈疝胎儿中显著高于正常胎儿(15.25±7.91° vs 7.68±1.55°,P<0.0001)。
  • 肝脏疝入组UVDA显著高于未疝入组(21.77±8.79° vs 10.75±2.10°,P<0.0001)。
  • UVDA预测肝脏疝入的AUC为0.94,最佳截断值15.2°,敏感度89%、特异度100%。

核心结论

  • 在先天性膈疝胎儿中,脐静脉弯曲可通过三维超声测量UVDA进行量化,该超声标志物似乎是左侧先天性膈疝胎儿肝脏疝入的准确预测指标。

研究设计与样本

  • 前瞻性纳入2009年至2015年间连续22例孤立性左侧先天性膈疝胎儿作为研究组,并选取88例正常胎儿作为对照;采集胎儿腹部三维超声容积,离线计算UVDA;随访所有膈疝病例的肝脏疝入情况。

关键影像表现/征象

  • UVDA由腹中线(连接椎体中心与脐带腹壁插入点)与连接椎体中心至脐静脉腹腔内凸出点的第二线构成。
  • 膈疝胎儿UVDA为15.25±7.91°,正常对照为7.68±1.55°,膈疝组显著增高(P<0.0001)。
  • 膈疝伴肝脏疝入胎儿UVDA为21.77±8.79°,未疝入者为10.75±2.10°,肝脏疝入组显著增高(P<0.0001)。

诊断标准与关键数值

  • UVDA预测左侧先天性膈疝胎儿肝脏疝入的ROC曲线下面积为0.94(P<0.0001),最佳截断值15.2°,对应敏感度89%、特异度100%(P<0.0001)。

临床应用与阅片要点

  • 作者认为,在左侧先天性膈疝胎儿中,三维超声测量UVDA似乎是预测肝脏疝入的准确超声标志物。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To introduce a new sonographic marker of intrathoracic liver herniation in fetuses with left-sided congenital diaphragmatic hernia (CDH).

METHODS: In a consecutive series of fetuses with isolated CDH, an ultrasound volume of the fetal abdomen was acquired. On this volume, offline calculation of the angle formed by the midline of the abdomen (joining the center of the vertebral body to the abdominal insertion of the umbilical cord) and a second line joining the center of the vertebral body to the intra-abdominal convexity of the umbilical vein was carried out to give the umbilical vein deviation angle (UVDA). The UVDA was measured in a group of normal fetuses selected as controls. At follow-up, the presence of liver herniation was investigated in all cases of CDH. UVDA values were compared between the CDH group and controls, and between CDH 'liver-up' vs 'liver-down' cases. A receiver-operating characteristics (ROC) curve was constructed to identify a cut-off value of the UVDA with the highest accuracy in predicting liver herniation in the CDH group.

RESULTS: Between 2009 and 2015, 22 cases of left-sided CDH were included in the study group, of which nine cases had liver herniation. Eighty-eight normal fetuses were recruited as controls. The UVDA was significantly higher in the cases vs controls (15.25 ± 7.91° vs 7.68 ± 1.55°; P < 0.0001). Moreover, the UVDA was significantly increased in CDH fetuses with liver-up vs liver-down (21.77 ± 8.79° vs 10.75 ± 2.10°; P < 0.0001). On ROC curve analysis the UVDA showed good prediction of liver herniation (area under the ROC curve, 0.94; P < 0.0001) with the best cut-off of 15.2°, yielding a sensitivity of 89% and a specificity of 100% (P < 0.0001).

CONCLUSIONS: In fetuses with CDH, umbilical vein bowing may be quantified by measuring the UVDA using three-dimensional ultrasound. This sonographic marker seems to be an accurate predictor of liver herniation in left-sided CDH. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Volpe N, Mazzone E, Muto B, et al. Three-dimensional assessment of umbilical vein deviation angle for prediction of liver herniation in left-sided congenital diaphragmatic hernia. Ultrasound Obstet Gynecol. 2017. PMID: 28078737. doi:10.1002/uog.17406

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。