文献速递头颈技术与安全US

虚拟触诊组织成像定量技术鉴别转移性与非转移性颈部淋巴结的初步评估

Preliminary Evaluation of Virtual Touch Tissue Imaging Quantification for Differential Diagnosis of Metastatic and Nonmetastatic Cervical Lymph Nodes.
PubMed 文献 · J Ultrasound Med · 2017-01-27

回顾性分析85例经病理证实的浅表淋巴结病变患者的常规超声与VTIQ图像,转移性淋巴结SWV值显著高于非转移性(P < .001)。以SWV 3.27 m/s为阈值鉴别转移性与非转移性淋巴结,AUC 0.953,准确率89.4%、敏感度88.6%、特异度90.2%;VTIQ可有效鉴别转移性与非转移性颈部淋巴结。

要点

  • 转移性淋巴结SWV值显著高于非转移性淋巴结(P < .001)。
  • SWV阈值3.27 m/s鉴别转移性与非转移性淋巴结,AUC 0.953,准确率89.4%。
  • SWV阈值3.27 m/s鉴别转移性与反应性增生淋巴结,AUC 0.968,特异度94.1%。

核心结论

  • VTIQ可有效鉴别转移性与非转移性颈部淋巴结。

研究设计与样本

  • 回顾性分析85例经病理证实的浅表淋巴结病变患者,先行常规超声描述二维图像,再测量VTIQ剪切波速度(SWV)值,以病理诊断为参考标准。

关键影像表现/征象

  • 转移性淋巴结SWV值显著高于非转移性淋巴结(P < .001)。

诊断标准与关键数值

  • SWV阈值3.27 m/s鉴别转移性与非转移性淋巴结:AUC 0.953,准确率89.4%、敏感度88.6%、特异度90.2%。
  • SWV阈值3.23 m/s鉴别转移性与血液/淋巴系统疾病淋巴结:AUC 0.943,准确率88.2%、敏感度88.6%、特异度87.5%。
  • SWV阈值3.27 m/s鉴别转移性与反应性增生淋巴结:AUC 0.968,准确率90.2%、敏感度88.6%、特异度94.1%。

临床应用与阅片要点

  • 测量浅表淋巴结VTIQ剪切波速度值,以3.27 m/s为阈值辅助鉴别转移性与非转移性颈部淋巴结。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Virtual Touch tissue imaging quantification (VTIQ; Siemens Medical Solutions, Mountain View, CA) is useful for assessing tissue hardness. This study aimed to investigate the value of VTIQ in differential diagnosis of cervical lymph nodes.

METHODS: We retrospectively analyzed conventional sonograms and VTIQ images of 85 pathologically confirmed patients with superficial lymph node lesions. Conventional sonography was first performed, with 2-dimensional images described. Then VTIQ shear wave velocity (SWV) values of superficial lymph nodes were measured. With pathologic diagnosis as the reference standard, a receiver operating characteristic curve was generated to evaluate VTIQ efficacy in differential diagnosis of metastatic and nonmetastatic cervical lymph nodes.

RESULTS: Of the 85 nodes, 44 and 41 were metastatic and nonmetastatic, respectively. The latter group included 24 and 17 hematologic/lymphatic system disease and reactive hyperplastic nodes, respectively. Shear wave velocity values of metastatic nodes were significantly higher than those of their nonmetastatic counterparts (P < .001). With an area under the curve (AUC) of 0.953 and SWV cutoff of 3.27 m/s, accuracy, sensitivity, and specificity were 89.4%, 88.6%, and 90.2%, respectively, for distinguishing metastatic and nonmetastatic nodes. An AUC of 0.943 and SWV cutoff of 3.23 m/s yielded accuracy, sensitivity, and specificity of 88.2%, 88.6%, and 87.5% for differentiating metastatic from hematologic/lymphatic system disease nodes. Finally, an AUC of 0.968 and SWV cutoff of 3.27 m/s yielded accuracy, sensitivity, and specificity of 90.2%, 88.6%, and 94.1% for differentiating metastatic from reactive hyperplastic nodes.

CONCLUSIONS: Virtual Touch tissue imaging quantification is efficient in differential diagnosis of metastatic and nonmetastatic cervical lymph nodes.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhao Y, Xi J, Zhao B, et al. Preliminary Evaluation of Virtual Touch Tissue Imaging Quantification for Differential Diagnosis of Metastatic and Nonmetastatic Cervical Lymph Nodes. J Ultrasound Med. 2017. PMID: 28127781. doi:10.7863/ultra.16.03077

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。