采用80 kVp和正弦图确认迭代重建的脑骨减影CT血管成像:对比剂与辐射剂量降低且图像质量改善

Cerebral bone subtraction CT angiography using 80 kVp and sinogram-affirmed iterative reconstruction: contrast medium and radiation dose reduction with improvement of image quality.
PubMed 文献 · Neuroradiology · 2017-01-03

本研究纳入75例接受脑骨减影CT血管成像的患者,比较120 kVp(37例,滤波反投影重建,对比剂370 mgI/kg)与80 kVp(38例,正弦图确认迭代重建,对比剂296 mgI/kg)两种方案。结果显示80 kVp方案的有效剂量降低62%(0.59±0.06 vs 1.56±0.13 mSv,p<0.01),颈内动脉和大脑中动脉的CT值及对比噪声比均显著高于120 kVp方案(p<0.01),颅底/夹闭部位附近血管可见性无显著差异(p=0.45),其余主观评分80 kVp方案更优(p<0.05)。

要点

  • 80 kVp联合正弦图确认迭代重建方案的有效剂量为0.59±0.06 mSv,较120 kVp联合滤波反投影方案的1.56±0.13 mSv降低62%。
  • 80 kVp方案对比剂用量为296 mgI/kg,低于120 kVp方案的370 mgI/kg。
  • 80 kVp方案颈内动脉和大脑中动脉的CT值及对比噪声比均显著高于120 kVp方案(p<0.01)。

核心结论

  • 与120 kVp联合滤波反投影方案相比,80 kVp联合正弦图确认迭代重建的脑骨减影CT血管成像图像质量更好,且辐射剂量和对比剂剂量均大幅降低。

研究设计与样本

  • 研究纳入75例接受脑骨减影CT血管成像的患者,其中120 kVp方案37例、80 kVp方案38例;120 kVp图像采用滤波反投影重建,80 kVp图像采用正弦图确认迭代重建。

关键影像表现/征象

  • 80 kVp方案颈内动脉CT值为557.4±105.7 HU,显著高于120 kVp方案的370.0±59.3 HU(p<0.01)。
  • 80 kVp方案大脑中动脉CT值为551.9±107.9 HU,显著高于120 kVp方案的364.6±62.2 HU(p<0.01)。
  • 80 kVp方案颈内动脉对比噪声比为46.2±10.2,显著高于120 kVp方案的36.9±7.6(p<0.01)。
  • 80 kVp方案大脑中动脉对比噪声比为45.7±10.0,显著高于120 kVp方案的35.7±9.0(p<0.01)。
  • 颅底/夹闭部位附近血管可见性两种方案无显著差异(p=0.45),其余主观评分80 kVp方案更高(p<0.05)。

诊断标准与关键数值

  • 对比剂剂量:120 kVp方案为370 mgI/kg,80 kVp方案为296 mgI/kg。
  • 有效剂量:80 kVp方案为0.59±0.06 mSv,120 kVp方案为1.56±0.13 mSv,80 kVp方案降低62%(p<0.01)。
  • 主观评分采用四点量表,评估动脉对比、锐利度、小动脉显示、颅底/夹闭部位附近血管可见性及整体图像质量。

临床应用与阅片要点

  • 80 kVp联合正弦图确认迭代重建可在降低辐射和对比剂剂量的同时改善脑骨减影CT血管成像的图像质量。
  • 颅底/夹闭部位附近血管可见性在80 kVp与120 kVp方案间无显著差异(p=0.45)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: The purpose of this study was to evaluate the feasibility of a contrast medium (CM), radiation dose reduction protocol for cerebral bone-subtraction CT angiography (BSCTA) using 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE).

METHODS: Seventy-five patients who had undergone BSCTA under the 120- (n = 37) or the 80-kVp protocol (n = 38) were included. CM was 370 mgI/kg for the 120-kVp and 296 mgI/kg for the 80-kVp protocol; the 120- and the 80-kVp images were reconstructed with filtered back-projection (FBP) and SAFIRE, respectively. We compared effective dose (ED), CT attenuation, image noise, and contrast-to-noise ratio (CNR) of two protocols. We also scored arterial contrast, sharpness, depiction of small arteries, visibility near skull base/clip, and overall image quality on a four-point scale.

RESULTS: ED was 62% lower at 80- than 120-kVp (0.59 ± 0.06 vs 1.56 ± 0.13 mSv, p < 0.01). CT attenuation of the internal carotid artery (ICA) and middle cerebral artery (MCA) was significantly higher on 80- than 120-kVp (ICA: 557.4 ± 105.7 vs 370.0 ± 59.3 Hounsfield units (HU), p < 0.01; MCA: 551.9 ± 107.9 vs 364.6 ± 62.2 HU, p < 0.01). The CNR was also significantly higher on 80- than 120-kVp (ICA: 46.2 ± 10.2 vs 36.9 ± 7.6, p < 0.01; MCA: 45.7 ± 10.0 vs 35.7 ± 9.0, p < 0.01). Visibility near skull base and clip was not significantly different (p = 0.45). The other subjective scores were higher with the 80- than the 120-kVp protocol (p < 0.05).

CONCLUSION: The 80-kVp acquisition with SAFIRE yields better image quality for BSCTA and substantial reduction in the radiation and CM dose compared to the 120-kVp with FBP protocol.

来源:Neuroradiology,查看原文。版权归原作者所有。