文献速递神经儿科影像CT

儿童头部CT:采用降低辐射剂量方案时ASIR-V改善图像质量

Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children.
PubMed 文献 · Eur Radiol · 2017-01-23

本研究在体模和小儿头部CT协议中评估ASIR-V重建的图像质量。体模研究显示提高ASIR-V百分比可降低噪声、提高CNR并保留空间分辨率;在儿童患者中,降低管电流并应用ASIR-V后,辐射剂量降低12.8%至34.0%,图像噪声更低、CNR更高,灰白质分界和锐利度定性评分更高,整体诊断质量得以保持。

要点

  • 儿童头部CT采用降低管电流联合ASIR-V,辐射剂量可降低12.8%至34.0%
  • ASIR-V重建图像噪声更低、CNR更高(半卵圆中心2.14 vs 1.52,P=0.003)
  • 定性分析显示ASIR-V图像灰白质分界和锐利度更高,整体诊断质量保持

核心结论

  • 使用ASIR-V可在各年龄组实现12.8%至34.0%的辐射剂量降低,并有可能改善图像质量。

研究设计与样本

  • 体模研究按标准儿童头部CT协议以每次递减20% mA扫描,每个研究按10% ASIR-V间隔重建;随后在<3岁患者协议中mA降低10%并应用30% ASIR-V,在3-15岁患者协议中mA降低30%并应用40% ASIR-V。

关键影像表现/征象

  • 体模研究中,提高ASIR-V百分比导致噪声降低、CNR升高,并保留空间分辨率。
  • 与常规协议相比,降低剂量联合ASIR-V的方案图像噪声更低(9.22 vs 10.73,P=0.043)。
  • 不同层面的CNR更高:半卵圆中心2.14 vs 1.52(P=0.003),基底节1.46 vs 1.07(P=0.001),小脑2.18 vs 1.33(P<0.001)。
  • 定性分析显示ASIR-V图像灰白质分界和锐利度更高,整体诊断质量保持。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the quality of images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V), using pediatric head CT protocols.

METHODS: A phantom was scanned at decreasing 20% mA intervals using our standard pediatric head CT protocols. Each study was then reconstructed at 10% ASIR-V intervals. After the phantom study, we reduced mA by 10% in the protocol for <3-year-old patients and applied 30% ASIR-V and by 30% in the protocol for 3- to 15-year-old patients and applied 40% ASIR-V.

RESULTS: Increasing the percentage of ASIR-V resulted in lower noise and higher contrast-to-noise ratio (CNR) and preserved spatial resolution in the phantom study. Compared to a conventional-protocol, reduced-dose protocol with ASIR-V achieved 12.8% to 34.0% of dose reduction and showed images of lower noise (9.22 vs. 10.73, P = 0.043) and higher CNR in different levels (centrum semiovale, 2.14 vs. 1.52, P = 0.003; basal ganglia, 1.46 vs. 1.07, P = 0.001; and cerebellum, 2.18 vs. 1.33, P < 0.001). Qualitative analysis showed higher gray-white matter differentiation and sharpness and preserved overall diagnostic quality in the images with ASIR-V.

CONCLUSIONS: Use of ASIR-V allowed a 12.8% to 34.0% dose reduction in each age group with potential to improve image quality.

KEY POINTS: • It is possible to reduce radiation dose and improve image quality with ASIR-V. • We improved noise and CNR and decreased radiation dose. • Sharpness improved with ASIR-V. • Total radiation dose was decreased by 12.8% to 34.0%.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kim HG, Lee HJ, Lee SK, et al. Head CT: Image quality improvement with ASIR-V using a reduced radiation dose protocol for children. Eur Radiol. 2017. PMID: 28116512. doi:10.1007/s00330-017-4733-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。