文献速递儿科影像技术与安全MR

胎儿死后全身磁共振成像:3-T与1.5-T磁共振成像与经典尸检的比较

Post-mortem whole-body magnetic resonance imaging of human fetuses: a comparison of 3-T vs. 1.5-T MR imaging with classical autopsy.
PubMed 文献 · Eur Radiol · 2017-01-23

本前瞻性研究于2012至2015年对135例流产、死产或终止妊娠后的胎儿行死后全身MRI,其中92例后续行经典尸检,比较3-T与1.5-T的诊断准确性。结果显示除眼眶和脑外,3-T MRI的诊断误差显著低于1.5-T,且在孕20周以下胎儿中该差异仍然存在;3-T与经典尸检的一致性更高,尤其在孕20周以下胎儿的胸部、心脏和腹部。

要点

  • 3-T MRI诊断误差在所有解剖结构和器官组中均显著低于1.5-T,但眼眶和脑除外。
  • 3-T MRI非诊断性扫描更少,与经典尸检一致性更高,尤其在孕20周以下胎儿的胸部、心脏和腹部。

核心结论

  • 死后胎儿3-T MRI较1.5-T提高置信度评分和总体准确性,主要体现在孕20周以下胎儿的胸部、心脏和腹部。

研究设计与样本

  • 前瞻性研究,2012至2015年对135例孕12-41周胎儿行死后1.5-T和3-T全身MRI,其中92例后续行经典尸检;采用置信度诊断评分评估临床MRI诊断,并与经典尸检比较得出诊断误差评分。

诊断标准与关键数值

  • 诊断准确性以置信度诊断评分和诊断误差评分评估,并与经典尸检比较;3-T MRI诊断误差显著低于1.5-T,眼眶和脑除外。
  • 3-T MRI较1.5-T非诊断性扫描更少,与经典尸检一致性更高,尤其孕20周以下胎儿的胸部、心脏和腹部。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To prospectively compare diagnostic accuracy of fetal post-mortem whole-body MRI at 3-T vs. 1.5-T.

METHODS: Between 2012 and 2015, post-mortem MRI at 1.5-T and 3-T was performed in fetuses after miscarriage/stillbirth or termination. Clinical MRI diagnoses were assessed using a confidence diagnostic score and compared with classical autopsy to derive a diagnostic error score. The relation of diagnostic error for each organ group with gestational age was calculated and 1.5-T with 3-T was compared with accuracy analysis.

RESULTS: 135 fetuses at 12-41 weeks underwent post-mortem MRI (followed by conventional autopsy in 92 fetuses). For all organ groups except the brain, and for both modalities, the diagnostic error decreased with gestation (P < 0.0001). 3-T MRI diagnostic error was significantly lower than that of 1.5-T for all anatomic structures and organ groups, except the orbits and brain. This difference was maintained for fetuses <20 weeks gestation. Moreover, 3-T was associated with fewer non-diagnostic scans and greater concordance with classical autopsy than 1.5-T MRI, especially for the thorax, heart and abdomen in fetuses <20 weeks.

CONCLUSION: Post-mortem fetal 3-T MRI improves confidence scores and overall accuracy compared with 1.5-T, mainly for the thorax, heart and abdomen of fetuses <20 weeks of gestation.

KEY POINTS: • In PM-MRI, diagnostic error using 3-T is lower than that with 1.5-T. • In PM-MRI, diagnostic scan rate is higher using 3-T than 1.5-T. • In PM-MRI, concordance with classical autopsy increases with 3-T. • PM-MRI using 3-T is particularly interesting for thoracic and abdominal organs. • PM-MRI using 3-T is particularly interesting for fetuses < 20 weeks' gestation.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kang X, Cannie MM, Arthurs OJ, et al. Post-mortem whole-body magnetic resonance imaging of human fetuses: a comparison of 3-T vs. 1.5-T MR imaging with classical autopsy. Eur Radiol. 2017. PMID: 28116518. doi:10.1007/s00330-016-4725-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。