文献速递神经介入DSAMRCT

时间分辨三维数字减影血管造影在脑动静脉畸形放射外科治疗计划中的应用

Application of Time-Resolved 3D Digital Subtraction Angiography to Plan Cerebral Arteriovenous Malformation Radiosurgery.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-01-26

本研究纳入20例接受伽玛刀放射外科治疗的脑动静脉畸形或硬脑膜动静脉瘘患者,探讨时间分辨三维DSA(4D-DSA)用于治疗计划制定的可行性。16例成功在Leksell GammaPlan中注册,立体定向4D-DSA的注册误差小于整合立体定向成像(P=.0009),4D-DSA勾画的动静脉畸形体积小于MR与2D-DSA整合勾画体积,但硬脑膜动静脉瘘病例存在较大不一致。结论认为立体定向4D-DSA用于伽玛刀放射外科治疗计划是可行的,可能有助于缩小血管性放射外科的照射靶体积。

要点

  • 立体定向4D-DSA注册误差小于整合立体定向成像(P=.0009)。
  • 4D-DSA勾画的动静脉畸形体积小于MR与2D-DSA整合勾画体积。
  • 硬脑膜动静脉瘘病例中两种方法勾画体积存在较大不一致。

核心结论

  • 立体定向4D-DSA数据用于脑动静脉畸形/硬脑膜动静脉瘘伽玛刀放射外科治疗计划是可行的;4D-DSA能在四个维度展示血管形态和血流动力学,可能缩小血管性放射外科的照射靶体积。

研究设计与样本

  • 前瞻性招募2014年11月至2015年10月连续20例(8例硬脑膜动静脉瘘、12例动静脉畸形;男13例、女7例;平均年龄45岁,范围18-64岁)计划接受伽玛刀放射外科治疗的患者;将重建的时间分辨三维容积切成类2D-CT图像,回顾性叠加原放射外科治疗计划,比较立体定向4D-DSA与整合立体定向成像的注册误差,并勾画动静脉畸形/硬脑膜动静脉瘘体积;采用Wilcoxon符号秩检验和Wilcoxon秩和检验评估注册误差与勾画体积。

诊断标准与关键数值

  • 20例中16例成功在Advanced Leksell GammaPlan程序中注册。
  • 立体定向4D-DSA的注册误差小于整合立体定向成像(P=.0009)。
  • 4D-DSA勾画的动静脉畸形体积小于MR成像与2D-DSA整合勾画的体积,两位作者测量对应的P值分别为.042和.039。
  • 硬脑膜动静脉瘘病例中两种方法勾画体积存在较大不一致(两位作者测量对应的P值分别为.042和.039)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Time-resolved 3D-DSA (4D-DSA) enables viewing vasculature from any desired angle and time frame. We investigated whether these advantages may facilitate treatment planning and the feasibility of using 4D-DSA as a single imaging technique in AVM/dural arteriovenous fistula radiosurgery.

MATERIALS AND METHODS: Twenty consecutive patients (8 dural arteriovenous fistulas and 12 AVMs; 13 men and 7 women; mean age, 45 years; range, 18-64 years) who were scheduled for gamma knife radiosurgery were recruited (November 2014 to October 2015). An optimal volume of reconstructed time-resolved 3D volumes that defines the AVM nidus/dural arteriovenous fistula was sliced into 2D-CT-like images. The original radiosurgery treatment plan was overlaid retrospectively. The registration errors of stereotactic 4D-DSA were compared with those of integrated stereotactic imaging. AVM/dural arteriovenous fistula volumes were contoured, and disjoint and conjoint components were identified. The Wilcoxon signed rank test and the Wilcoxon rank sum test were adopted to evaluate registration errors and contoured volumes of stereotactic 4D-DSA and integration of stereotactic MR imaging and stereotactic 2D-DSA.

RESULTS: Sixteen of 20 patients were successfully registered in Advanced Leksell GammaPlan Program. The registration error of stereotactic 4D-DSA was smaller than that of integrated stereotactic imaging (P = .0009). The contoured AVM volume of 4D-DSA was smaller than that contoured on the integration of MR imaging and 2D-DSA, while major inconsistencies existed in cases of dural arteriovenous fistula (P = .042 and 0.039, respectively, for measurements conducted by 2 authors).

CONCLUSIONS: Implementation of stereotactic 4D-DSA data for gamma knife radiosurgery for brain AVM/dural arteriovenous fistula is feasible. The ability of 4D-DSA to demonstrate vascular morphology and hemodynamics in 4 dimensions potentially reduces the target volumes of irradiation in vascular radiosurgery.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Chen KK, Guo WY, Yang HC, et al. Application of Time-Resolved 3D Digital Subtraction Angiography to Plan Cerebral Arteriovenous Malformation Radiosurgery. AJNR Am J Neuroradiol. 2017. PMID: 28126751. doi:10.3174/ajnr.A5074

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。