受控超声诱导开放后血脑屏障关闭时间与开放体积无关
研究用微泡介导聚焦超声开放大鼠血脑屏障,比较单点与四点重叠 sonication 后开放体积及关闭时间;多点的横截面积约为单点 3.5 倍,但 10 个半球中 9 个在 6 小时关闭,余 1 个在 24 小时关闭,提示在所研究时间尺度上关闭时间与开放体积无关。
要点
- 多点 sonication 的开放横截面积约为单点的 3.5 倍(14.2 vs 4.1 mm²,P < .0001)。
- 10 个半球中 9 个在 6 小时关闭,余 1 个 6 小时增强明显减低、24 小时关闭。
- 6 小时与 24 小时 T2 加权未见水肿,6 小时 T2* 加权未见出血。
核心结论
- 在所研究的时间尺度上,聚焦超声后血脑屏障关闭时间与开放体积无关。
研究设计与样本
- 动物实验:Sprague Dawley 大鼠 n = 5,双侧聚焦超声,一侧单点 sonication、对侧 4 个重叠焦点;用对比增强 T1 加权 MRI 在 0、6、24 小时评估血脑屏障完整性。
关键影像表现/征象
- 0 小时单点与多点 sonication 的平均强化无显著差异(均值 ± 标准差,29.7% ± 18.4% 对 29.7% ± 24.1%;P = .9975)。
- 多点 sonication 所致血脑屏障开放的横截面积约为单点的 3.5 倍(14.2 ± 4.7 对 4.1 ± 3.3 mm²;P < .0001)。
- 6 小时与 24 小时 T2 加权图像未见水肿征象。
- 6 小时 T2* 加权图像在任何动物中均未见出血征象。
临床应用与阅片要点
- 作者认为较大体积的血脑屏障开放可以安全进行。
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Microbubble-mediated focused ultrasound (US) opening of the blood-brain barrier (BBB) has shown promising results for the treatment of brain tumors and conditions such as Alzheimer disease. Practical clinical implementation of focused US treatments would aim to treat a substantial portion of the brain; thus, the safety of opening large volumes must be investigated. This study investigated whether the opened volume affects the time for the BBB to be restored after treatment.
METHODS: Sprague Dawley rats (n = 5) received bilateral focused US treatments. One hemisphere received a single sonication, and the contralateral hemisphere was targeted with 4 overlapping foci. Contrast-enhanced T1-weighted magnetic resonance imaging was used to assess the integrity of the BBB at 0, 6, and 24 hours after focused US.
RESULTS: At time 0, there was no significant difference in the mean enhancement between the single- and multi-point sonications (mean ± SD, 29.7% ± 18.4% versus 29.7% ± 24.1%; P = .9975). The mean cross-sectional area of the BBB opening resulting from the multi-point sonication was approximately 3.5-fold larger than that of the single-point case (14.2 ± 4.7 versus 4.1 ± 3.3 mm2 ; P < .0001). The opened volumes in 9 of 10 hemispheres were closed by 6 hours after focused US. The remaining treatment location had substantially reduced enhancement at 6 hours and was closed by 24 hours. Histologic analysis revealed small morphologic changes associated with this location. T2-weighted images at 6 and 24 hours showed no signs of edema. T2*-weighted images obtained at 6 hours also showed no signs hemorrhage in any animal.
CONCLUSIONS: The time for the BBB to close after focused US was independent of the opening volume on the time scale investigated. No differences in treatment effects were observable by magnetic resonance imaging follow-up between larger- and smaller-volume sonications, suggesting that larger-volume BBB opening can be performed safely.
引用
- O'Reilly MA, Hough O, Hynynen K, et al. Blood-Brain Barrier Closure Time After Controlled Ultrasound-Induced Opening Is Independent of Opening Volume. J Ultrasound Med. 2017. PMID: 28108988. doi:10.7863/ultra.16.02005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。