静音扫描非增强MR血管成像在基底动脉尖动脉瘤Y型支架辅助弹簧圈栓塞术后随访中的价值
本研究对7例接受Y型支架辅助弹簧圈栓塞治疗的基底动脉尖动脉瘤患者行静音MRA、3D TOF-MRA和DSA检查,以DSA为参考标准。静音MRA显示支架内血流的评分(4.07±0.70)高于3D TOF-MRA(1.93±0.80,P<.05),且静音MRA对瘤颈残留的显示与DSA相似(5例均显示),而3D TOF-MRA仅显示1例。静音MRA可能有助于Y型支架辅助弹簧圈栓塞术后的随访。
要点
- 静音MRA显示支架内血流的评分高于3D TOF-MRA(4.07±0.70 vs 1.93±0.80,P<.05)。
- 静音MRA对瘤颈残留的显示与DSA相似(5例均显示),3D TOF-MRA仅显示1例。
- 静音MRA可能有助于Y型支架辅助弹簧圈栓塞术后随访。
核心结论
- 静音MRA可能有助于Y型支架辅助弹簧圈栓塞术后的随访。
研究设计与样本
- 7例接受Y型支架辅助弹簧圈栓塞治疗的基底动脉尖动脉瘤患者,行静音MRA、3D TOF-MRA和DSA检查;静音MRA与3D TOF-MRA在同一扫描时段于3T MR成像系统获得;两名神经放射学家独立阅片,以最新DSA图像为参考标准,对支架内血流进行1(不可见)至5(几乎等同DSA)的主观评分,并评估瘤颈残留的显示情况。
诊断标准与关键数值
- 以DSA为参考标准,对支架内血流的评分标准为1分(不可见)至5分(几乎等同DSA);静音MRA平均评分4.07±0.70,3D TOF-MRA平均评分1.93±0.80(P<.05);DSA显示瘤颈残留5例,静音MRA显示5例且与DSA相似,3D TOF-MRA仅显示1例。
临床应用与阅片要点
- 作者认为静音MRA可能有助于Y型支架辅助弹簧圈栓塞术后的随访。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Y-configuration stent-assisted coil embolization is used for treating wide-neck aneurysms. Noninvasive alternatives to x-ray DSA for follow-up after Y-configuration stent-assisted coil embolization treatment are required. This study aimed to assess the usefulness of non-contrast-enhanced MRA by using a Silent Scan (silent MRA) for follow-up after Y-configuration stent-assisted coil embolization for basilar tip aneurysms.
MATERIALS AND METHODS: Seven patients treated with Y-configuration stent-assisted coil embolization for basilar tip aneurysms underwent silent MRA, 3D TOF-MRA, and DSA. Silent MRA and 3D TOF-MRA images were obtained during the same scan session on a 3T MR imaging system. Two neuroradiologists independently reviewed both types of MRA images and subjectively scored the flow in the stents on a scale of 1 (not visible) to 5 (nearly equal to DSA) by referring to the latest DSA image as a criterion standard. Furthermore, we evaluated the visualization of the neck remnant.
RESULTS: In all patients, the 2 observers gave a higher score for the flow in the stents on silent MRA than on 3D TOF-MRA. The average score ± standard deviation was 4.07 ± 0.70 for silent MRA and 1.93 ± 0.80 (P < .05) for 3D TOF-MRA. Neck remnants were depicted by DSA in 5 patients. In silent MRA, neck remnants were depicted in 5 patients, and visualization was similar to DSA; however, in 3D TOF-MRA, neck remnants were depicted in only 1 patient.
CONCLUSIONS: Silent MRA might be useful for follow-up after Y-configuration stent-assisted coil embolization.
引用
- Takano N, Suzuki M, Irie R, et al. Usefulness of Non-Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms. AJNR Am J Neuroradiol. 2016. PMID: 28007767. doi:10.3174/ajnr.A5033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。