文献速递介入技术与安全

以患者为中心的放射学流程模型试点研究

Pilot Study of a Patient-Centered Radiology Process Model.
PubMed 文献 · J Am Coll Radiol · 2016-12-04

在100例接受门诊介入放射学操作的患者中试点应用放射学流程模型(RPM)调查表,24个条目按4–5级严重程度评分。RPM汇总量表与视觉模拟量表(VAS)强相关(r=0.7),因子分析提取4个因子,内部一致性α=0.86。结论认为RPM初步显示心理测量学效度和内部一致性信度,广泛使用前需小幅修改。

要点

  • RPM调查表含24个条目、每项4–5级严重程度,在门诊介入放射学患者中完成。
  • RPM汇总评分与患者介入放射学体验VAS强相关(r=0.7)。
  • 因子分析提取设施与医生/员工互动、时间相关方面、疼痛、焦虑4个因子。

核心结论

  • RPM初步显示心理测量学效度和内部一致性信度,预计在更广泛使用前需小幅修改。

研究设计与样本

  • 经机构审查委员会批准的试点RPM调查,纳入100例接受门诊介入放射学操作的患者。
  • 调查表共24个条目,每个条目设4或5级严重程度。
  • 评估缺失数据、患者认为困惑的条目、患者对新增条目的建议及条目清晰度,并进行因子分析和内部一致性测量。
  • 结构效度通过将患者对各条目的应答汇总为量表分,与患者完成的介入放射学体验视觉模拟量表(VAS)做相关分析来评估。

诊断标准与关键数值

  • RPM汇总量表与VAS强相关(r=0.7)。
  • 因子分析显示4个因子:与设施及医生/员工的互动、时间敏感方面、疼痛、焦虑。
  • 条目整体内部一致性高(α=0.86),各因子约为0.7至0.9。
  • 分析显示可删除两个条目(费用和放射科医生与转诊医生之间的沟通)。

临床应用与阅片要点

  • 原文讨论了对两个条目的修订及可能新增其他条目,未给出具体修订内容。

局限性

  • 试点研究,预计在更广泛使用前需小幅修改。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The Radiology Process Model (RPM) was previously described in terms of its conceptual basis and proposed survey items. The current study describes the first pilot application of the RPM in the field and the results of initial psychometric analysis.

METHODS: We used an Institutional Review Board-approved pilot RPM survey in 100 patients having outpatient interventional radiology procedures. The 24 survey items had 4 or 5 levels of severity. We assessed for missing data, items that patients found confusing, any suggestions by patients for additional items and clarity of items from patient feedback. Factor analysis was performed and internal consistency measured. Construct validity was assessed by correlation of patient responses to the items as a summated scale with a visual analog scale (VAS) they completed indicating their interventional radiology experience.

RESULTS: The visual analog scale and the RPM summated scale were strongly correlated (r = 0.7). Factor analysis showed four factors: interactions with facility and doctors/staff, time-sensitive aspects, pain, and anxiety. The items showed high internal consistency (alpha: 0.86) as a group and approximately 0.7 to 0.9 by the factors. Analysis shows that two items could be deleted (cost and communication between radiologist and referrers). Revision of two items and potential addition of others are discussed.

CONCLUSIONS: The RPM shows initial evidence of psychometric validity and internal consistency reliability. Minor changes are anticipated before wider use.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Swan JS, Furtado VF, Keller LA, et al. Pilot Study of a Patient-Centered Radiology Process Model. J Am Coll Radiol. 2016. PMID: 27927589. doi:10.1016/j.jacr.2016.08.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。