CT引导下微波消融治疗骨样骨瘤的前瞻性初步研究
这项前瞻性初步研究纳入13例骨样骨瘤患者,评估CT引导下微波消融的可行性与疗效。首次术后1个月完全疼痛缓解且随访MRI显示瘤巢坏死的成功率为92.3%(12/13);中位功率60 W、中位消融时间1.5分钟,平均坏死灶23×15×16 mm。作者结论认为成功率似乎与激光或射频消融接近,但需注意预防神经或皮肤损伤。
要点
- CT引导下微波消融骨样骨瘤成功率92.3%(12/13),以术后1个月疼痛完全缓解且MRI示瘤巢坏死为成功标准。
- 中位消融功率60 W、中位时间1.5分钟,平均坏死范围23×15×16 mm。
- 观察到1例桡神经感觉支部分性自愈性损伤和2例皮肤烧伤,需注意预防神经或皮肤损伤。
核心结论
- CT引导下微波消融治疗骨样骨瘤的成功率似乎与激光或射频消融接近,但需注意预防神经或皮肤损伤。
研究设计与样本
- 前瞻性初步研究,连续纳入13例骨样骨瘤患者(年龄11–31岁),接受CT引导下微波消融,记录功率与时间,用NRS评估疼痛,用增强MRI评估瘤巢血管化与坏死体积,成功定义为首次术后1个月疼痛完全缓解且随访MRI显示瘤巢坏死。
关键影像表现/征象
- 增强MRI用于评估瘤巢血管化及微波消融诱导的坏死体积。
- 微波消融诱导的坏死灶平均测量为23×15×16 mm。
诊断标准与关键数值
- 成功定义为首次术后1个月疼痛完全缓解,并伴随访MRI显示瘤巢坏死。
- 成功率92.3%(12/13)。
- 术后1天、7天、1个月的中位NRS分别为5(IQR 2–5)、0(IQR 0–1)、0(IQR 0–0)。
- 中位微波消融功率60 W(IQR 50–60),中位持续时间1.5分钟(IQR 1–2)。
临床应用与阅片要点
- 作者结论认为CT引导下微波消融骨样骨瘤的成功率似乎与激光或射频消融接近,但需注意预防神经或皮肤损伤。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aims of this work were to assess the feasibility and efficacy of CT-guided microwave ablation (MWA) in the treatment of osteoid osteomas (OOs).
MATERIALS AND METHODS: Thirteen consecutive patients (range 11-31 years old) presenting with OO were prospectively included and treated by CT-guided MWA. Power and duration of MWA were both recorded. The patient's pain was assessed using a numeric pain rating scale (NRS), and side effects were recorded during procedures, after 1 day, 7 days and 1 month. The nidus vascularization and the volume of necrosis induced by MWA were assessed using contrast-enhanced MRI. Success was defined as the complete relief of the patient's pain 1 month after the first procedure, associated with necrosis of the nidus on follow-up MRI.
RESULTS: The success rate was up to 92.3% (12/13). At 1 day, 7 days and 1 month, the median NRSs were respectively 5 [interquartile range (IQR) 2-5], 0 (IQR 0-1) and 0 (IQR 0-0). Side effects observed were one partial and self-resolving lesion of a sensory branch of the radial nerve and two skin burns. The median power of the MWA used was 60 W (IQR 50-60) with a 1.5-min duration (IQR 1-2), leading to MWA-induced necrosis measuring on average 23 × 15 × 16 mm.
CONCLUSION: CT-guided MWA of OO has a success rate that appears to be almost similar to that of laser or radiofrequency ablation, but care must be taken to prevent nerve or skin lesions.
引用
- Prud'homme C, Nueffer JP, Runge M, et al. Prospective pilot study of CT-guided microwave ablation in the treatment of osteoid osteomas. Skeletal Radiol. 2016. PMID: 28028574. doi:10.1007/s00256-016-2558-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。