文献速递骨肌US

肌肌腱连接处的定量弹性超声:功能测试中的正常表现及其与标准测量系统的相关性

Quantitative Elastosonography of the Myotendinous Junction: Normal Behavior and Correlation With a Standard Measurement System During Functional Tests.
PubMed 文献 · J Ultrasound Med · 2016-11-30

研究对19名男性职业足球运动员在功能测试中行实时弹性超声检查,评估股直肌肌肌腱连接处弹性行为,并与标准测力系统对比。结果显示肌肉收缩时弹性值下降,左腿30°离心收缩时弹性值与力峰值及平均做功呈负相关(Pearson r分别为-0.53和-0.51),提示弹性超声定量似乎符合肌肌腱连接处的生理和生物力学行为。

要点

  • 肌肉收缩时肌肌腱连接处弹性值下降,放松时较高。
  • 右侧股直肌放松时弹性值30.75%±10.05%,收缩时13.75%±8.44%。
  • 左侧股直肌收缩前36.48%±8.39%,收缩时8.77%±6.55%。

核心结论

  • 肌肌腱连接处的应变弹性超声定量似乎符合其预期的生理和生物力学行为。

研究设计与样本

  • 对19名男性职业足球运动员在功能测试中行弹性超声检查,使用测力-功率测量系统和配备18-6 MHz多频线阵探头的超声仪。

关键影像表现/征象

  • 右侧股直肌放松时弹性值30.75%±10.05%,收缩时13.75%±8.44%,平均下降17.00%±11.71%。
  • 左侧股直肌收缩前弹性值36.48%±8.39%,收缩时8.77%±6.55%,平均下降27.71%±11.95%。

诊断标准与关键数值

  • 左腿30°离心收缩时,弹性值与力峰值的Pearson r为-0.53。
  • 左腿30°离心收缩时,弹性值与平均做功的Pearson r为-0.51。

临床应用与阅片要点

  • 弹性超声定量可用于评估肌肌腱连接处在肌肉收缩时的弹性变化,似乎与生理和生物力学行为相符。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: In recent years, an increasing need to use imaging to assess normal and adaptive muscle function, in addition to its anatomy and structure, has emerged. We evaluated the myotendinous junction's elastosonographic behavior in light of the most recent literature on its physiologic behavior. The elastosonographic studies were compared with the results obtained from a standard measurement system to ensure a correlation with maximal muscle contraction.

METHODS: Nineteen male professional soccer players were assessed during functional tests. The participants performed 5 repetitions at 60°/s to assess muscle strength and 3 repetitions at 30°/s to assess the maximum force peak of thigh muscles. The participants were monitored by a strength-power measurement system and an ultrasound machine equipped with multifrequency (18-6-MHz) linear array transducers.

RESULTS: The 19 soccer players were aged between 19 and 34 years (mean age, 28 years). For the right rectus femoris, the results of the elastosonographic studies showed a mean elasticity value ± SD of 30.75% ± 10.05% with the muscle relaxed and a value of 13.75% ± 8.44% during contraction (mean decrease, 17.00% ± 11.71%). Elasticity values were 36.48% ± 8.39% before contraction and 8.77% ± 6.55% during contraction of the left rectus femoris muscle (mean decrease, 27.71% ± 11.95%). For 30° eccentric contraction of the left leg, correlation with the standard measurement system showed Pearson r values of -0.53 and -0.51 when comparing force peak and mean work, respectively, with elasticity values.

CONCLUSIONS: Our study shows that strain elastosonographic quantification of muscle elasticity seems to match the expected physiologic and biomechanical behavior of the myotendinous junction.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Minafra P, Bortolotto C, Rampinini E, et al. Quantitative Elastosonography of the Myotendinous Junction: Normal Behavior and Correlation With a Standard Measurement System During Functional Tests. J Ultrasound Med. 2016. PMID: 27925702. doi:10.7863/ultra.15.11023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。