短暂性骨髓水肿综合征与骨坏死:高时间分辨率动态对比增强MR灌注模式可资鉴别
前瞻性纳入32例患者(26髋、10膝),在3 T行常规MR及高时间分辨率动态对比增强三维扰相梯度回波序列,定量分析平均通过时间(MTT)与血浆流量(PF)参数图。短暂性骨髓水肿综合征(TBMES)表现为软骨下高PF、低MTT的细长区域,周围环绕长MTT、低PF区;骨坏死表现为邻近关节面的软骨下低或无可测PF区及MTT区,周围环绕高PF、中等MTT的环状边缘;两者灌注模式不重叠。
要点
- TBMES软骨下呈高PF、低MTT细长区,周围环绕长MTT、低PF区。
- 骨坏死软骨下呈低或无可测PF区,周围环绕高PF、中等MTT环状边缘。
- 两者灌注模式不重叠,软骨下即刻区PF差异有统计学意义(P < .001)。
核心结论
- 高时间分辨率动态对比增强MR所得参数图可鉴别髋、膝关节的骨坏死与短暂性骨髓水肿综合征。
研究设计与样本
- 前瞻性研究,经机构审查委员会批准并获书面知情同意,纳入32例患者(21男、11女,平均年龄48岁;26髋、10膝),在3 T行常规MR及动态对比增强三维扰相梯度回波序列,评估MTT与PF参数图。
关键影像表现/征象
- TBMES关节表现为软骨下高PF、低MTT的细长区域,周围环绕长MTT、低PF区。
- 骨坏死关节表现为邻近关节面的软骨下低或无可测PF区及MTT区,周围环绕高PF、中等MTT的环状边缘。
- TBMES与骨坏死的灌注模式不重叠。
诊断标准与关键数值
- TBMES与骨坏死软骨下即刻区PF差异有统计学意义(P < .001);骨坏死该区PF与背景噪声相当,无法定量。
- 仅见于骨坏死关节的高PF、中等MTT环状边缘,PF均值±标准差为18.9 mL/100 mL每分钟±11.0,MTT均值±标准差为213.3秒±56.8。
- 周围区域MTT(P = .09)与PF(P = .75)在TBMES与骨坏死间无显著差异。
临床应用与阅片要点
- 阅片时结合MTT与PF参数图,注意软骨下即刻区的PF高低及周围环状边缘的有无,用于鉴别TBMES与骨坏死。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To prospectively evaluate the perfusion patterns at quantitative dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging of transient bone marrow edema syndrome (TBMES) and avascular osteonecrosis. Materials and Methods Institutional review board approval and written informed consent were obtained. Thirty-two patients (21 men, 11 women; mean age, 48 years; 26 hips, 10 knees) underwent conventional MR imaging and a dynamic contrast-enhanced three-dimensional spoiled gradient-echo sequence at 3 T. Parameter maps for mean transit time (MTT) and plasma flow (PF) were evaluated qualitatively and quantitatively. Differences in perfusion patterns were analyzed by using the Fisher exact test. Regions of interest were drawn in areas of high PF and long MTT on each parametric map. Mean, median, standard deviation, minimum, and maximum values were determined. TBMES and osteonecrosis were compared statistically by using the Mann-Whitney U and Wilcoxon signed-rank tests, with a P value of less than .05 considered indicative of a significant difference. Results Nineteen joints with TBMES and 17 joints with osteonecrosis were evaluated. TBMES joints showed a subchondral elongated area of high PF and low MTT that was surrounded by an area of long MTT and low PF. Osteonecrosis joints showed a subchondral area with low or no detectable PF and MTT adjacent to the joint surface, which was surrounded by a rim of high PF and intermediate MTT. Patterns for TBMES and osteonecrosis did not overlap. A significant difference (P < .001) in PF in the immediate subchondral area was found between TBMES and osteonecrosis; in joints with osteonecrosis, this was comparable to background noise, and therefore, could not be quantified. In the circumscribed rim of high PF and intermediate MTT, which was only found in joints with osteonecrosis, mean ± standard deviation PF was 18.9 mL/100 mL per minute ± 11.0 and mean MTT was 213.3 seconds ± 56.8. No significant difference between TBMES and osteonecrosis was found for MTT (P = .09) and PF (P = .75) in the surrounding area. Conclusion Parameter maps derived at dynamic contrast-enhanced MR imaging with high temporal resolution can allow differentiation of osteonecrosis from TBMES in hip and knee joints. © RSNA, 2016 Online supplemental material is available for this article.
引用
- Geith T, Niethammer T, Milz S, et al. Transient Bone Marrow Edema Syndrome versus Osteonecrosis: Perfusion Patterns at Dynamic Contrast-enhanced MR Imaging with High Temporal Resolution Can Allow Differentiation. Radiology. 2016. PMID: 27905865. doi:10.1148/radiol.2016152665
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。