增加低强度脉冲超声时长及功能矫治器对生长期大鼠下颌髁突的影响
研究将54只生长期SD大鼠分为6组,比较每日20或40分钟低强度脉冲超声单独或联合功能矫治器对下颌髁突生长的影响;20分钟超声组多数指标显著增加,而功能矫治器联合40分钟超声组效果最差;作者结论为每日20分钟低强度脉冲超声可影响生长期大鼠下颌生长,需更长观察期研究长期效果。
要点
- 每日20分钟低强度脉冲超声组多数测量指标显著增加(P < .05),但髁突进程长度除外(P = .18)。
- 功能矫治器联合40分钟超声组结果最不理想。
- 20分钟超声组较40分钟超声组增殖细胞和肥大细胞计数及宽度增加,骨小梁微结构增强。
核心结论
- 每日20分钟低强度脉冲超声在生长期大鼠中可影响下颌生长,单独或联合功能矫治器均可;需更长观察期研究长期效果和新骨稳定性。
研究设计与样本
- 将54只Sprague Dawley大鼠分为6组(每组n=9):对照组、20分钟低强度脉冲超声组、40分钟低强度脉冲超声组、功能矫治器组、功能矫治器联合20分钟超声组、功能矫治器联合40分钟超声组;低强度脉冲超声应用28天,处死后行形态学、组织形态学和微型CT分析。
关键影像表现/征象
- 20分钟超声组增殖细胞和肥大细胞计数及宽度增加,骨小梁微结构增强,均优于40分钟超声组。
- 功能矫治器联合20分钟超声组结果优于功能矫治器单独组和功能矫治器联合40分钟超声组。
- 功能矫治器联合40分钟超声组在所有研究组中结果最不理想。
局限性
- 作者指出需要更长观察期的进一步研究来探讨长期效果和新形成骨的稳定性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Functional appliances are used for treatment of lower-jaw deficiencies in growing individuals; however, their effectiveness is debatable. Low-intensity pulsed ultrasound (US) is a noninvasive method, which has been shown to stimulate cartilage and bone formation with 20 minutes of application. This study was designed to test the hypothesis that increasing low-intensity pulsed US application from 20 to 40 min/d will enhance mandibular condylar growth in growing rats, especially when combined with a functional appliance.
METHODS: Fifty-four Sprague Dawley rats were divided into 6 groups (n = 9): control, low-intensity pulsed US for 20 minutes, low-intensity pulsed US for 40 minutes, the functional appliance, the functional appliance plus low-intensity pulsed US for 20 minutes, and the functional appliance plus low-intensity pulsed US for 40 minutes. Low-intensity pulsed US was applied for 28 days. All rats were then euthanized, and their mandibles were dissected for morphometric, histomorphometric, and micro-computed tomographic analyses.
RESULTS: Among all study groups, the 20-minute US group showed significant increases in most of the measured variables (P < .05) except for condylar process length (P = .18), whereas the functional appliance-plus-40-min US group showed the least favorable results. The 20-minute US group showed increases in proliferative and hypertrophic cell counts and widths and enhanced microarchitecture of trabecular bone compared with the 40-minute US group. The functional appliance-plus-20-minute US group showed better results compared with the functional appliance-alone and functional appliance-plus-40-minute US groups.
CONCLUSIONS: A daily application of low-intensity pulsed US for 20 minutes in growing rats affects mandibular growth, either alone or in combination with a functional appliance. Further study with a longer observation period is required to study the long-term effects and stability of newly formed bone.
引用
- Kaur H, Uludağ H, Dederich DN, et al. Effect of Increasing Low-Intensity Pulsed Ultrasound and a Functional Appliance on the Mandibular Condyle in Growing Rats. J Ultrasound Med. 2016. PMID: 27925675. doi:10.7863/ultra.15.06063
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。