文献速递骨肌MR

非关节造影3T磁共振成像评估股骨髋臼撞击症髋关节内病变的准确性

Accuracy of non-arthrographic 3T MR imaging in evaluation of intra-articular pathology of the hip in femoroacetabular impingement.
PubMed 文献 · Skeletal Radiol · 2016-12-14

回顾性分析42例疑似股骨髋臼撞击症患者,以髋关节镜为标准,评估非关节造影3T磁共振对盂唇撕裂和软骨病变的诊断准确性。磁共振诊断盂唇撕裂敏感度100%、特异度50%、准确率98%,股骨软骨异常敏感度85%、特异度100%、准确率95%,髋臼软骨病变敏感度94%、特异度67%、准确率90%。作者认为非关节造影3T磁共振是评估盂唇和软骨的高准确性技术。

要点

  • 非关节造影3T磁共振诊断盂唇撕裂敏感度100%、准确率98%,但特异度仅50%。
  • 股骨软骨异常诊断特异度100%、准确率95%,髋臼软骨病变敏感度94%、特异度67%。
  • 髋臼软骨病变磁共振分级与关节镜在10例中不一致。

核心结论

  • 非关节造影3T磁共振成像在临床疑似股骨髋臼撞击症患者中评估盂唇和软骨具有高准确性。

研究设计与样本

  • 经IRB批准并豁免知情同意,回顾性分析42例连续疑似股骨髋臼撞击症病例,均行非关节造影3T磁共振和髋关节镜;由两名骨肌放射科医生在不知关节镜结果情况下共识评估高分辨率TSE磁共振图像,以关节镜为标准参考计算敏感度、特异度、准确率和预测值。

关键影像表现/征象

  • 磁共振显示41例盂唇撕裂,敏感度100%、特异度50%、准确率98%、阳性预测值98%、阴性预测值100%。
  • 磁共振显示11例股骨软骨异常,敏感度85%、特异度100%、准确率95%、阳性预测值100%、阴性预测值94%。
  • 磁共振显示36例髋臼软骨病变,敏感度94%、特异度67%、准确率90%、阳性预测值94%、阴性预测值67%。
  • 36例髋臼软骨病变中,7例为变性/裂隙,26例为分层,3例为剥脱。
  • 磁共振与关节镜对关节软骨分级在10例中结果不一致。

诊断标准与关键数值

  • 以髋关节镜为参考标准,磁共振诊断盂唇撕裂敏感度100%、特异度50%、准确率98%、阳性预测值98%、阴性预测值100%。
  • 磁共振诊断股骨软骨异常敏感度85%、特异度100%、准确率95%、阳性预测值100%、阴性预测值94%。
  • 磁共振诊断髋臼软骨病变敏感度94%、特异度67%、准确率90%、阳性预测值94%、阴性预测值67%。
  • 髋臼软骨分级:正常、变性/裂隙、分层、剥脱。

临床应用与阅片要点

  • 非关节造影3T磁共振可用于评估疑似股骨髋臼撞击症患者的盂唇和软骨。
  • 磁共振诊断盂唇撕裂特异度50%,需注意假阳性可能。
  • 髋臼软骨病变磁共振分级与关节镜存在不一致,阅片时需谨慎。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the accuracy of non-arthrographic 3-T MRI compared to hip arthroscopy in the assessment of labral and cartilaginous pathology in patients with suspected FAI.

MATERIALS AND METHODS: Following IRB approval and waived consent, 42 consecutive cases of suspected FAI with non-arthrographic 3-T MRI and arthroscopy of the hip were reviewed. High-resolution TSE MR imaging was evaluated in consensus by two musculoskeletal radiologists, blinded to arthroscopic findings, for the presence of labral tears and articular cartilage lesions. Acetabular cartilage was categorized as normal, degeneration/fissuring, delamination, or denudation. MRI findings were compared to arthroscopy. Sensitivity, specificity, accuracy, and predictive values for MRI were calculated using arthroscopy as the standard of reference.

RESULTS: Forty-two hips in 38 patients with a mean age of 29 (range 13-45 years) were assessed. Mean interval between MRI and arthroscopy was 154 days (range 27-472 days). MRI depicted 41 cases with labral tears (sensitivity 100%, specificity 50%, accuracy 98%, PPV 98%, NPV 100%), 11 cases with femoral cartilage abnormalities (sensitivity 85%, specificity 100%, accuracy 95%, PPV 100%, NPV 94%), and 36 cases with acetabular cartilage lesions (sensitivity 94% specificity 67%, accuracy 90%, PPV 94%, NPV 67%). Of the 36 cases with acetabular cartilage lesions on MRI, 7 were characterized as degeneration/fissuring, 26 as delamination, and 3 as denudation, with discordant results between MRI and arthroscopy for grading of articular cartilage in ten cases.

CONCLUSION: Non-arthrographic 3-T MR imaging is a highly accurate technique for evaluation of the labrum and cartilage in patients with clinically suspected FAI.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Linda DD, Naraghi A, Murnaghan L, et al. Accuracy of non-arthrographic 3T MR imaging in evaluation of intra-articular pathology of the hip in femoroacetabular impingement. Skeletal Radiol. 2016. PMID: 27975135. doi:10.1007/s00256-016-2551-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。