有症状手骨关节炎的指间关节超声检查:临床与功能相关性
这项前瞻性双盲研究纳入60个指间关节、每年由临床医生和超声医师各评估6次,共720个测量凹陷(掌侧360、背侧360),评估灰阶滑膜肥厚与能量多普勒表现同临床及功能评估的相关性。近端指间关节背侧定量测量与关节肿胀(P=.043)和指尖捏力(P=.043)相关,掌侧定量测量与关节肿胀(P=.007)、澳大利亚/加拿大(AUSCAN)功能指数(P=.044)及握力和手指力量相关;远端指间关节未发现相关性或关联;能量多普勒信号仅见于1.7%的样本。结论为关节肿胀、握力和捏力及AUSCAN指数与近端指间关节超声表现呈弱相关和关联,观察者内和观察者间超声评估可靠。
要点
- 近端指间关节背侧定量测量与关节肿胀及捏力相关(P=.043)。
- 近端指间关节掌侧定量测量与关节肿胀、AUSCAN功能指数及握力和手指力量相关。
- 远端指间关节未发现超声表现与临床或功能评估的相关性或关联。
核心结论
- 关节肿胀、握力和捏力及AUSCAN指数与近端指间关节超声表现呈弱相关和关联,观察者内和观察者间超声评估可靠。
研究设计与样本
- 前瞻性双盲研究,纳入60个指间关节,由临床医生和超声医师观察者每年评估6次,共720个测量凹陷(掌侧360个、背侧360个)。
关键影像表现/征象
- 近端指间关节背侧定量测量与关节肿胀(P=.043)和指尖捏力(P=.043)呈统计学相关。
- 近端指间关节掌侧定量测量与关节肿胀(P=.007)、AUSCAN功能指数(P=.044)及握力和手指力量(P=.037、.003、.019、.017)呈统计学相关。
- 背侧半定量评估与关节肿胀(P=.010)及捏力(P=.027、.003、.014)存在关联;掌侧凹陷与AUSCAN指数(P=.048)及握力和手指力量(P=.031、.006、.041)存在关联。
- 远端指间关节未发现相关性或关联。
- 能量多普勒信号仅见于1.7%的样本,无法进行统计分析。
诊断标准与关键数值
- 排除远端指间关节掌侧半定量评估(P=.623)后,超声表现可靠,组内相关系数为0.474-0.857,κ=0.390-0.673。
局限性
- 能量多普勒信号仅见于1.7%的样本,无法进行统计分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the correlation between inflammatory sonographic findings (grayscale synovial hypertrophy and power Doppler) and clinical and functional assessments in hand osteoarthritis (symptomatic interphalangeal joints) and to correlate the intraobserver and interobserver reliability of these findings.
METHODS: A prospective double-blind study of 60 interphalangeal joints was conducted. The joints were assessed 6 times per year by clinician and sonographer observers.
RESULTS: A total of 720 measurement recesses were included (360 palmar and 360 dorsal). Small correlations and a few associations were found. Proximal interphalangeal joint quantitative measurements of the dorsal recess showed a statistical correlation with joint swelling (P = .043) and pulp-to-pulp pinch strength (P = .043); in the palmar recess, statistical correlations were seen for joint swelling (P = .007), the Australian/Canadian (AUSCAN) Function Index (P = .044), and grip and finger strength (P = .037, .003, .019, and .017). In dorsal semiquantitative assessments, there were associations between sonographic findings and joint swelling (P = .010) and pinch strength (P = .027, .003, and .014); in the palmar recess, we found associations with the AUSCAN Index (P = .048) and grip and finger strength (P = .031, .006, and 0.041). No correlations or associations were found in distal interphalangeal joints. Power Doppler signals were found in only 1.7% of the sample, precluding statistical analysis. Excluding palmar semiquantitative assessments in distal interphalangeal joints (P = .623), sonographic findings were reliable (intraclass correlation coefficients, 0.474-0.857; κ = 0.390-0.673).
CONCLUSIONS: Joint swelling, grip and pinch strength, and the AUSCAN Index were weakly correlated and associated with sonographic findings in proximal interphalangeal joints. Intraobserver and interobserver sonographic assessments were reliable.
引用
- Spolidoro Paschoal NO, Natour J, Machado FS, et al. Interphalangeal Joint Sonography of Symptomatic Hand Osteoarthritis: Clinical and Functional Correlation. J Ultrasound Med. 2016. PMID: 27914183. doi:10.7863/ultra.16.01031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。