盂肱关节不稳患者肩关节3D-MR与3D-CT的对比研究

3D-MR vs. 3D-CT of the shoulder in patients with glenohumeral instability.
PubMed 文献 · Skeletal Radiol · 2016-12-27

前瞻性纳入12个因盂肱关节不稳需同时接受CT和MRI检查的肩关节,两者相隔24小时内完成,MRI含轴位3D各向同性VIBE序列。3D-MR与3D-CT后处理图像在肱骨头及肩胛盂高度宽度、Hill-Sachs尺寸及肱骨头骨缺损百分比、肩胛盂骨缺损尺寸及百分比测量差异无统计学意义,在1mm和1.5%等价界值下等效。

要点

  • 3D-MR骨性重建模型与3D-CT模型在肩关节骨性测量上等效。
  • 两种模态测量差异无统计学意义,肱骨高度、肩胛盂高度及宽度差异仅边缘性显著。
  • 轴位3D各向同性VIBE序列可用于盂肱关节不稳的骨性结构评估。

核心结论

  • 使用3D各向同性VIBE序列的肩关节3D-MR骨性模型与3D-CT骨性模型等效,两种模态间差异无统计学意义。

研究设计与样本

  • 前瞻性研究,12个肩关节,CT与MR在24小时内完成,MR包含轴位3D各向同性VIBE序列,CT和MR数据均经3D软件后处理,采用配对t检验及双单侧等价检验。

关键影像表现/征象

  • 3D-MR与3D-CT后处理图像测量肱骨头和肩胛盂高度宽度、Hill-Sachs尺寸及肱骨头骨缺损百分比、肩胛盂骨缺损尺寸及百分比。
  • 两种模态测量差异无统计学意义,肱骨高度、肩胛盂高度及肩胛盂宽度差异为边缘性统计学显著,经多重比较校正后不显著。

诊断标准与关键数值

  • 以1mm为测量等价界值、1.5%为骨缺损百分比等价界值,3D-MR与3D-CT后处理图像等效。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine whether 3D-MR osseous reformats of the shoulder are equivalent to 3D-CT osseous reformats in patients with glenohumeral instability.

MATERIALS AND METHODS: Patients with glenohumeral instability, who were to be imaged with both CT and MRI, were prospectively selected. CT and MR were performed within 24 h of one another on 12 shoulders. Each MR study included an axial 3D isotropic VIBE sequence. The image data from the isotropic VIBE sequence were post-processed using subtraction and 3D software. CT data were post-processed using 3D software. The following measurements were obtained for both 3D-CT and 3D-MR post-processed images: height and width of the humeral head and glenoid, Hill-Sachs size and percent humeral head loss (if present), size of glenoid bone loss and percent glenoid bone loss (if present). Paired t-tests and two one-sided tests for equivalence were used to assess the differences between imaging modalities and equivalence.

RESULTS: The measurement differences from the 3D-CT and 3D-MR post-processed images were not statistically significant. The measurement differences for humeral height, glenoid height and glenoid width were borderline statistically significant; however, using any adjustment for multiple comparisons, this failed to be significant. Using an equivalence margin of 1 mm for measurements and 1.5% for percent bone loss, the 3D-MR and 3D-CT post-processed images were equivalent.

CONCLUSION: Three-dimensional-MR osseous models of the shoulder using a 3D isotropic VIBE sequence were equivalent to 3D-CT osseous models, and the differences between modalities were not statistically significant.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Stillwater L, Koenig J, Maycher B, et al. 3D-MR vs. 3D-CT of the shoulder in patients with glenohumeral instability. Skeletal Radiol. 2016. PMID: 28028575. doi:10.1007/s00256-016-2559-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。