文献速递骨肌CT

低剂量站立位CT扫描仪测量胫股关节间隙宽度的重测信度

Test-retest reliability of tibiofemoral joint space width measurements made using a low-dose standing CT scanner.
PubMed 文献 · Skeletal Radiol · 2016-12-01

前瞻性两访视研究纳入30名受试者50个膝关节,采用低剂量站立位CT在间隔2周时重复采集胫股关节几何数据,评估各阈值下关节间隙宽度小于阈值面积百分比的重测信度。结果显示各阈值ICC为外侧0.95-0.97、内侧0.90-0.97,RMSE外侧1.1-7.2%、内侧3.1-9.1%,较小阈值重复性更好,提示低剂量站立位CT可作为评估膝骨关节炎关节间隙的平片替代方案。

要点

  • 低剂量站立位CT测量胫股关节间隙宽度各阈值ICC为外侧0.95-0.97、内侧0.90-0.97。
  • RMSE外侧1.1-7.2%、内侧3.1-9.1%,较小关节间隙阈值重复性更好。
  • 作者认为低剂量站立位CT可作为评估膝骨关节炎关节间隙的平片替代方案。

核心结论

  • 本研究所用膝关节定位方案在间隔2周重复进行站立位CT三维胫股关节间隙宽度汇总测量时表现出高逐日信度,低剂量站立位CT在保持高信度的同时提供大量关节信息,作者认为其可作为评估膝骨关节炎患者关节间隙的平片替代方案。

研究设计与样本

  • 前瞻性两访视研究,纳入30名受试者共50个膝关节(66%女性,平均年龄58.2±11.3岁,BMI 29.1±5.6 kg/m²,38%为KL 0-1级),采用双侧约20°固定屈曲站立位CT在间隔2周时采集胫股关节几何数据。

诊断标准与关键数值

  • 每个间室总关节面积定义为关节间隙宽度小于10 mm的区域。
  • 汇总测量指标为每个胫股间室中关节间隙宽度小于2.0至5.0 mm之间各0.5 mm阈值区域的面积百分比。
  • 各阈值ICC为外侧0.95-0.97、内侧0.90-0.97。
  • RMSE为外侧1.1-7.2%、内侧3.1-9.1%,较小关节间隙阈值重复性更好。

临床应用与阅片要点

  • 作者认为低剂量站立位CT可作为评估膝骨关节炎患者关节间隙的平片替代方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine the test-retest reliability of knee joint space width (JSW) measurements made using standing CT (SCT) imaging.

SUBJECTS AND METHODS: This prospective two-visit study included 50 knees from 30 subjects (66% female; mean ± SD age 58.2 ± 11.3 years; BMI 29.1 ± 5.6 kg/m2; 38% KL grade 0-1). Tibiofemoral geometry was obtained from bilateral, approximately 20° fixed-flexed SCT images acquired at visits 2 weeks apart. For each compartment, the total joint area was defined as the area with a JSW <10 mm. The summary measurements of interest were the percentage of the total joint area with a JSW less than 0.5-mm thresholds between 2.0 and 5.0 mm in each tibiofemoral compartment. Test-retest reliability of the summary JSW measurements was assessed by intraclass correlation coefficients (ICC 2,1) for the percentage area engaged at each threshold of JSW and root-mean-square errors (RMSE) were calculated to assess reproducibility.

RESULTS: The ICCs were excellent for each threshold assessed, ranging from 0.95 to 0.97 for the lateral and 0.90 to 0.97 for the medial compartment. RMSE ranged from 1.1 to 7.2% for the lateral and from 3.1 to 9.1% for the medial compartment, with better reproducibility at smaller JSW thresholds.

CONCLUSION: The knee joint positioning protocol used demonstrated high day-to-day reliability for SCT 3D tibiofemoral JSW summary measurements repeated 2 weeks apart. Low-dose SCT provides a great deal of information about the joint while maintaining high reliability, making it a suitable alternative to plain radiographs for evaluating JSW in people with knee OA.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Segal NA, Bergin J, Kern A, et al. Test-retest reliability of tibiofemoral joint space width measurements made using a low-dose standing CT scanner. Skeletal Radiol. 2016. PMID: 27909787. doi:10.1007/s00256-016-2539-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。