剪切波超声弹性成像评估肩袖肌腱

Shear Wave Ultrasound Elastographic Evaluation of the Rotator Cuff Tendon.
PubMed 文献 · J Ultrasound Med · 2016-12-03

回顾性分析19例有症状患者21次检查及16名无症状志愿者和6例无症状对侧肩共55次检查,用剪切波弹性成像测量肩袖肌腱近端和远端剪切波速度并与形态分级比较。形态分级与剪切波速度呈弱至中度负相关,有症状患者近端肌腱剪切波速度轻度降低(P = .049),三角肌剪切波速度在有症状肩显著降低(P = .001)。作者认为剪切波弹性成像可显示肩袖病变的肌腱软化,但与症状相关性差,可能更适用于术前肌腱质量评估而非肩痛检查。

要点

  • 肩袖肌腱形态分级越高(异常越重),近端和远端剪切波速度越低,呈弱至中度负相关。
  • 有症状患者仅近端肌腱剪切波速度较无症状者轻度降低(P = .049),远端无显著差异。
  • 三角肌剪切波速度在形态异常和有症状肩中也降低,其意义有待进一步探索。

核心结论

  • 剪切波弹性成像可显示肩袖病变中的肌腱软化,提供形态学评估之外的信息,但与症状相关性差,可能更适用于术前肌腱质量评估而非肩痛检查;形态异常和有症状患者中的三角肌软化需要进一步探索。

研究设计与样本

  • 回顾性研究,纳入19例因肩痛行常规超声检查的合格患者共21次检查,并与16名无症状志愿者和6例无症状对侧肩共55次检查比较;采用剪切波弹性成像测量肩袖肌腱近端和远端平均剪切波速度,并按1至4级(正常至全层撕裂)对形态进行分级;68次检查有三角肌剪切波速度用于事后分析;重复检查通过重采样处理。

关键影像表现/征象

  • 肩袖肌腱近端和远端形态分级与剪切波速度呈弱至中度负相关(近端 P < .001,远端 P = .002)。
  • 有症状患者近端肌腱剪切波速度较无症状者轻度降低(P = .049),远端肌腱无显著差异。
  • 三角肌剪切波速度与近端(P = .004)和远端(P = .007)肌腱形态分级呈弱至中度负相关。
  • 有症状肩的三角肌剪切波速度显著低于无症状肩(P = .001)。

诊断标准与关键数值

  • 肌腱形态分级采用1至4级:1级为正常,4级为全层撕裂。
  • 弹性评估指标为近端和远端肩袖肌腱的平均剪切波速度。

临床应用与阅片要点

  • 阅片时可结合B模式形态分级与剪切波速度测量,注意肌腱软化与形态异常相关。
  • 剪切波弹性成像与症状相关性差,作者认为其用于肩痛检查的价值可能低于术前肌腱质量评估。
  • 三角肌剪切波速度降低见于形态异常和有症状患者,作者指出需要进一步探索。

局限性

  • 原文结论指出,剪切波弹性成像与症状相关性差,其在肩痛检查中的用处可能不如术前肌腱质量评估。
  • 原文结论指出,形态异常和有症状患者中观察到的三角肌软化需要进一步探索。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: (1) Assess the association between the B-mode morphologic appearance and elasticity in the rotator cuff tendon using shear wave elastography (SWE). (2) Assess the association between SWE and symptoms.

METHODS: Institutional Review Board approval and informed consent were obtained. A retrospective review identified 21 studies in 19 eligible patients for whom SWE was performed during routine sonographic evaluations for shoulder pain. Evaluations were compared with 55 studies from 16 asymptomatic volunteers and 6 patients with asymptomatic contralateral shoulders. Repeated studies were accounted for by resampling. Proximal and distal tendon morphologic characteristics were graded from 1 to 4 (normal to full-thickness tear), and average shear wave velocity (SWV) measurements were obtained at both locations. In 68 examinations, deltoid muscle SWV measurements were available for post hoc analysis.

RESULTS: The morphologic grade and SWV showed weak-to-moderate negative correlations in the proximal (P < .001) and distal (P = .002) rotator cuff tendon. A weakly significant SWV decrease was found in the proximal tendon in symptomatic patients (P = .049); no significant difference was seen in the distal tendon. The deltoid muscle SWV showed weak-to-moderate negative correlations with the morphologic grade in the proximal (P = .004) and distal (P = .007) tendon; the deltoid SWV was also significantly lower in symptomatic shoulders (P = .001).

CONCLUSIONS: Shear wave elastography shows tendon softening in rotator cuff disease. It captures information not obtained by a morphologic evaluation alone; however, a poor correlation with symptoms suggests that SWE will be less useful in workups for shoulder pain than for preoperative assessments of tendon quality. Deltoid muscle softening seen in morphologically abnormal and symptomatic patients requires further exploration.