文献速递甲状腺与浅表US

对比增强超声图像异质性算法在实性甲状腺结节鉴别诊断中的应用

An Algorithm of Image Heterogeneity with Contrast-Enhanced Ultrasound in Differential Diagnosis of Solid Thyroid Nodules.
PubMed 文献 · Ultrasound Med Biol · 2016-10-28

研究采用对比增强超声(CEUS)量化实性甲状腺结节的增强异质性,计算异质性值(HV)为强度标准差/均值×100,异质性比(HR)为结节HV与周围实质HV之比,分析上升期、峰值期和下降期。恶性结节在上升期和峰值期的HV值及三个时相的HR值均显著高于良性结节,其中上升期HR诊断性能最优。该算法可能成为常规超声鉴别实性甲状腺结节的有用辅助手段。

要点

  • 恶性结节上升期HV为95.57±43.87,良性结节为73.06±44.04,恶性显著更高(p=0.009)。
  • 恶性结节峰值期HV为32.53±10.73,良性结节为26.44±8.25,恶性显著更高(p=0.002)。
  • 上升期HR在恶性结节为1.93±1.03,良性结节为1.00±0.47,恶性显著更高(p=0.000),ROC曲线分析诊断性能最优。

核心结论

  • CEUS图像异质性评估算法可能作为常规超声鉴别实性甲状腺结节的有用辅助手段。

研究设计与样本

  • 研究采用Adobe Photoshop计算实性甲状腺结节的异质性值(HV)和异质性比(HR),分析上升期、峰值期和下降期三个时相,以ROC曲线分析评估诊断性能。

关键影像表现/征象

  • 恶性结节上升期HV为95.57±43.87,良性结节为73.06±44.04,恶性显著更高(p=0.009)。
  • 恶性结节峰值期HV为32.53±10.73,良性结节为26.44±8.25,恶性显著更高(p=0.002)。
  • 恶性结节上升期HR为1.93±1.03,良性结节为1.00±0.47,恶性显著更高(p=0.000)。
  • 恶性结节峰值期HR为1.43±0.51,良性结节为1.09±0.28,恶性显著更高(p=0.000)。
  • 恶性结节下降期HR为1.33±0.40,良性结节为1.08±0.33,恶性显著更高(p=0.001)。

诊断标准与关键数值

  • 上升期HR在ROC曲线分析中达到最优诊断性能。

临床应用与阅片要点

  • CEUS图像异质性算法可能作为常规超声鉴别实性甲状腺结节的有用辅助手段。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Enhancement heterogeneity on contrast-enhanced ultrasonography (CEUS) is used to differentiate between benign and malignant thyroid nodules. In this study, we used an algorithm to quantify enhancement heterogeneity of solid thyroid nodules on CEUS. The heterogeneity value (HV) is calculated as standard deviation/mean intensity × 100 (using Adobe Photoshop). The heterogeneity ratio (HR) is calculated as the ratio of the HV of the nodule to that of the surrounding parenchyma. Three phases-ascending, peak and descending phases-were studied. HV values at ascending (HVa) and peak (HVp) phases were significantly higher in malignant nodules than in benign nodules (95.57 ± 43.87 vs. 73.06 ± 44.04, p = 0.009, and 32.53 ± 10.73 vs. 26.44 ± 8.25, p = 0.002, respectively). HRa, HRp and HRd were significantly higher in malignant nodules than in benign nodules (1.93 ± 1.03 vs. 1.00 ± 0.47, p = 0.000, 1.43 ± 0.51 vs. 1.09 ± 0.28, p = 0.000, and 1.33 ± 0.40 vs. 1.08 ± 0.33, p = 0.001, respectively). HRa achieved optimal diagnostic performance on receiver operating characteristic curve analysis. The algorithm used for assessment of image heterogeneity on CEUS examination may be a useful adjunct to conventional ultrasound for differential diagnosis of solid thyroid nodules.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Jin L, Xu C, Xie X, et al. An Algorithm of Image Heterogeneity with Contrast-Enhanced Ultrasound in Differential Diagnosis of Solid Thyroid Nodules. Ultrasound Med Biol. 2016. PMID: 28029495. doi:10.1016/j.ultrasmedbio.2016.05.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。