文献速递乳腺MRPET

高时间分辨率DCE MRI在同步PET/MRI系统中衍生的药代动力学参数在乳腺癌中的作用:一项可行性研究

Role of pharmacokinetic parameters derived with high temporal resolution DCE MRI using simultaneous PET/MRI system in breast cancer: A feasibility study.
PubMed 文献 · Eur J Radiol · 2016-11-25

本研究纳入98名女性109个乳腺病灶,利用3T同步PET/MRI系统行高时间分辨率DCE MRI,在60秒时间点计算Ktrans、Kep和ve。ROC分析显示Ktrans、Kep、ve的截断值分别为0.50、2.59、0.15,可区分乳腺良恶性病灶,总体准确率分别为94.50%、79.82%和87.16%。引入外部体模进行天然T1归一化后准确率提高至94.50%,特异度由84%升至87%。

要点

  • Ktrans截断值0.50时区分乳腺良恶性病灶的总体准确率为94.50%。
  • Kep和ve的总体准确率分别为79.82%和87.16%。
  • 天然T1归一化后特异度由84%升至87%,准确率由93.50%升至94.50%。

核心结论

  • 在3T MRI嵌入的PET/MRI系统中,以缩短的采集时间可靠测量药代动力学参数是可行的,具有合理的准确率,其应用可能扩展至进一步利用同步PET/MRI在乳腺癌中的潜力。

研究设计与样本

  • 可行性研究,纳入98名女性109个乳腺病灶,使用3T同步PET/MRI系统行高时间分辨率DCE MRI(作为常规乳腺MRI诊断或作为PET/MRI癌症分期的一部分),采用本院开发的计算方案在60秒时间点计算药代动力学参数Ktrans、ve和Kep。

诊断标准与关键数值

  • ROC曲线分析得出Ktrans、Kep、ve的截断值分别为0.50、2.59、0.15,可可靠区分乳腺良恶性病灶;Ktrans、Kep、ve的总体准确率分别为94.50%、79.82%、87.16%;引入外部体模进行天然T1归一化后准确率为94.50%,高于未归一化的93.50%,特异度分别为87% vs 84%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the reliability of pharmacokinetic parameters like Ktrans, Kep and ve derived through DCE MRI breast protocol using 3T Simultaneous PET/MRI (3Tesla Positron Emission Tomography/Magnetic Resonance Imaging) system in distinguishing benign and malignant lesions.

MATERIALS AND METHODS: High temporal resolution DCE (Dynamic Contrast Enhancement) MRI performed as routine breast MRI for diagnosis or as a part of PET/MRI for cancer staging using a 3T simultaneous PET/MRI system in 98 women having 109 breast lesions were analyzed for calculation of pharmacokinetic parameters (Ktrans, ve, and Kep) at 60s time point using an in-house developed computation scheme.

RESULTS: Receiver operating characteristic (ROC) curve analysis revealed a cut off value for Ktrans, Kep, ve as 0.50, 2.59, 0.15 respectively which reliably distinguished benign and malignant breast lesions. Data analysis revealed an overall accuracy of 94.50%, 79.82% and 87.16% for Ktrans, Kep, ve respectively. Introduction of native T1 normalization with an externally placed phantom showed a higher accuracy (94.50%) than without native T1 normalization (93.50%) with an increase in specificity of 87% vs 84%.

CONCLUSION: Overall the results indicate that reliable measurement of pharmacokinetic parameters with reduced acquisition time is feasible in a 3TMRI embedded PET/MRI system with reasonable accuracy and application may be extended to exploit the potential of simultaneous PET/MRI in further work on breast cancer.

来源:Eur J Radiol,查看原文。版权归原作者所有。