预压对乳腺病灶血流能量多普勒评估的影响

Effect of Precompression on the Power Doppler Assessment of Breast Lesion Vascularity.
PubMed 文献 · J Ultrasound Med · 2016-11-30

本研究纳入30例乳腺肿块患者(良性16例、恶性14例),用计算程序定量分析不同预压程度下能量多普勒彩色像素数变化。结果显示,常规B模式成像时的预压即可显著减少彩色体素;使彩色像素减少100%所需的预压百分比在良恶性间差异有统计学意义(P=.027),定量评估时需控制预压。

要点

  • 常规B模式成像时的预压即可明显减少能量多普勒显示的彩色体素。
  • 使彩色像素减少100%所需预压:良性34.7%±12.33% vs 恶性26.7%±3.89%(P=.027)。
  • 进行乳腺病灶多普勒定量评估时,预压需要控制。

核心结论

  • 常规B模式成像时施加的预压即可明显减少能量多普勒的彩色体素数量,对乳腺病灶进行多普勒定量评估时需控制预压。

研究设计与样本

  • 经机构审查委员会批准、符合《健康保险流通与责任法案》的研究,纳入30例乳腺肿块患者(良性16例、恶性14例)行超声引导下乳腺活检,用计算数学程序计算不同探头压压下感兴趣区内的彩色像素数。

诊断标准与关键数值

  • 使彩色体素减少50%所需预压百分比:良性15.9%±6.43%(范围8%-30%),恶性14.0%±4.17%(范围8%-20%),P=.35;使彩色像素减少100%所需预压百分比:良性34.7%±12.33%(范围23%-62%),恶性26.7%±3.89%(范围18%-31%),P=.027。

临床应用与阅片要点

  • 原文结论指出:进行乳腺病灶多普勒定量评估时,预压需要控制;原文未据此给出具体操作推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the effect of precompression on power Doppler visualization of blood flow in breast masses.

METHODS: This Institutional Review Board-approved and Health Insurance Portability and Accountability Act-compliant study evaluated 30 patients with breast masses (16 benign and 14 malignant) undergoing ultrasound-guided breast biopsy. A computational mathematics program was used to calculate the number of color pixels in a region of interest at various degrees of compression of the breast by the transducer. The amount of precompression was calculated as previously described. The percentage of color pixels compared to minimal compression was plotted against the percentage of precompression. The amount of precompression needed to decrease the number of color pixels by 50% and 100% was calculated. The differences between benign and malignant lesions were compared.

RESULTS: The mean percentages of precompression ± SD needed to decrease the number of color voxels by 50% in were 15.9% ± 6.43% (range, 8%-30%) for benign lesions and 14.0% ± 4.17% (range, 8%-20%) for malignant lesions (P = .35). The percentages of precompression needed to decrease the number of color pixels by 100% in were 34.7% ± 12.33% (range, 23%-62%) for benign lesions and for malignant lesions 26.7% ± 3.89% (range, 18%-31%), which were statistically significant (P = .027).

CONCLUSIONS: The amount of precompression normally used when obtaining B-mode images can substantially decrease the number of color voxels on power Doppler sonography. When performing quantitative work on Doppler evaluation of breast lesions, precompression needs to be controlled.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. DeVita R, Barr RG. Effect of Precompression on the Power Doppler Assessment of Breast Lesion Vascularity. J Ultrasound Med. 2016. PMID: 27925701. doi:10.7863/ultra.16.01024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。