简化流程磁共振成像在致密乳腺组织乳腺癌筛查中的应用
研究纳入478例致密乳腺且钼靶阴性的女性,分别用简化流程(AP)和全诊断流程(FDP)MRI筛查乳腺癌。FDP检出16例,AP检出15例;两者敏感度无显著差异(χ²=0.592,P=0.623),特异度有统计学显著差异(χ²=4.619,P=0.036);AUC分别为0.931±0.025和0.947±0.024,诊断能力无统计学显著差异。作者认为AP可能提高致密乳腺乳腺癌检出率,可能有助于高效筛查。
要点
- 致密乳腺且钼靶阴性者中,AP MRI检出15例乳腺癌,FDP检出16例。
- AP与FDP敏感度无显著差异(χ²=0.592,P=0.623),特异度有统计学显著差异(χ²=4.619,P=0.036)。
- AP与FDP的AUC分别为0.931±0.025和0.947±0.024,诊断能力无统计学显著差异。
核心结论
- 作者认为AP MRI可能提高致密乳腺组织乳腺癌检出率,并可能有助于高效乳腺癌筛查。
研究设计与样本
- 研究纳入478例致密乳腺且钼靶阴性的女性参与者,分别使用MRI的AP和FDP进行成像,AP与FDP图像分开分析,计算乳腺癌检出敏感度和特异度,采用卡方检验和受试者工作特征曲线评估两种方案的诊断能力。
诊断标准与关键数值
- FDP检出16例乳腺癌,病理证实为9例导管原位癌、6例浸润性导管癌和1例黏液癌。
- AP成功筛查出15例乳腺癌。
- AP与FDP敏感度无显著差异(χ²=0.592,P=0.623),特异度有统计学显著差异(χ²=4.619,P=0.036)。
- AP与FDP的AUC分别为0.931±0.025和0.947±0.024,两者诊断乳腺癌能力无统计学显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The study aimed to evaluate the usefulness of an abbreviated protocol (AP) of magnetic resonance imaging (MRI) in comparison to a full diagnostic protocol (FDP) of MRI in the breast cancer screening with dense breast tissue.
MATERIALS AND METHODS: There are 478 female participants with dense breast tissue and negative mammography results, who were imaged with MRI using AP and FDP. The AP and FDP images were analyzed separately, and the sensitivity and specificity of breast cancer detection were calculated. The chi-square test and receiver operating characteristics curves were used to assess the breast cancer diagnostic capabilities of the two protocols.
RESULTS: Sixteen cases of breast cancer from 478 patients with dense breasts were detected using the FDP method, with pathologic confirmation of nine cases of ductal carcinoma in situ, six cases of invasive ductal carcinoma, and one case of mucinous carcinoma. Fifteen cases of breast cancer were successfully screened using the AP method. The sensitivity showed no obvious significant difference between AP and FDP (χ2 = 0.592, P = 0.623), but the specificity showed a statistically significant difference (χ2 = 4.619, P = 0.036). The receiver operating characteristics curves showed high efficacy of both methods in the detection of breast cancer in dense breast tissue (the areas under the curve were 0.931 ± 0.025 and 0.947 ± 0.024, respectively), and the ability to diagnose breast cancer was not statistically significantly different between the two methods.
CONCLUSIONS: The AP of MRI may improve the detection rate of breast cancer in dense breast tissue, and it may be useful in efficient breast cancer screening.
引用
- Chen SQ, Huang M, Shen YY, et al. Application of Abbreviated Protocol of Magnetic Resonance Imaging for Breast Cancer Screening in Dense Breast Tissue. Acad Radiol. 2016. PMID: 27916594. doi:10.1016/j.acra.2016.10.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。