文献速递乳腺技术与安全US

早期乳腺癌中可疑腋窝淋巴结超声成像与细针穿刺活检在后ACOSOG Z11时代的相关性

The Relevance of Ultrasound Imaging of Suspicious Axillary Lymph Nodes and Fine-needle Aspiration Biopsy in the Post-ACOSOG Z11 Era in Early Breast Cancer.
PubMed 文献 · Acad Radiol · 2016-12-01

该单中心回顾性研究纳入128例T1或T2期乳腺癌伴超声异常腋窝淋巴结并接受细针穿刺活检(FNA)及腋窝手术的患者,评估FNA准确性及超声特征对FNA阳性的预测价值。FNA敏感度80%、特异度85.7%,阳性FNA与腋窝手术阳性相关(OR 22.7)。皮质厚度和异常门部为FNA阳性的预测特征,准确度0.817。

要点

  • FNA诊断腋窝淋巴结转移的敏感度80%、特异度85.7%,准确度AUC 0.801。
  • 超声征象中皮质厚度和异常门部可预测FNA阳性,准确度AUC 0.817。
  • 阳性FNA与腋窝手术阳性显著相关(OR 22.7,95%CI 7.2-71.3)。

核心结论

  • 超声成像和FNA在后Z11时代的早期乳腺癌管理中可发挥重要作用,超声评估时应更重视皮质厚度和门部。

研究设计与样本

  • 单中心回顾性研究,3年内758例病理证实的乳腺癌中,128例T1或T2期肿瘤伴超声异常腋窝淋巴结、接受FNA并后续行腋窝手术;以腋窝手术为参考标准,采用多变量逻辑回归分析超声特征对FNA阳性的预测价值。

关键影像表现/征象

  • 超声图像分析显示皮质厚度和异常门部是可预测FNA阳性的特征(P < .017)。

诊断标准与关键数值

  • FNA敏感度52/65(80%),特异度54/63(85.7%),阳性预测值52/61(85.2%),阴性预测值54/67(80.5%)。
  • FNA准确度AUC 0.801(95%CI 0.727-0.876)。
  • 校正FNA与手术间的新辅助化疗后,阳性FNA与腋窝手术阳性相关,OR 22.7(95%CI 7.2-71.3,P < .0001)。
  • 皮质厚度和异常门部预测FNA阳性的准确度AUC 0.817(95%CI 0.741-0.893)。

临床应用与阅片要点

  • 在早期乳腺癌腋窝超声评估中,可更重视皮质厚度和异常门部这两个征象。
  • FNA结果与腋窝手术病理相关性高,但需结合临床情况解读。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Evaluation of nodal involvement in early-stage breast cancers (T1 or T2) changed following the Z11 trial; however, not all patients meet the Z11 inclusion criteria. Hence, the relevance of ultrasound imaging of the axilla and fine-needle aspiration biopsy (FNA) in early-stage breast cancers was investigated.

MATERIALS AND METHODS: In this single-center, retrospective study, 758 subjects had pathology-verified breast cancer diagnosis over a 3-year period, of which 128 subjects with T1 or T2 breast tumors had abnormal axillary lymph nodes on ultrasound, had FNA, and proceeded to axillary surgery. Ultrasound images were reviewed and analyzed using multivariable logistic regression to identify the features predictive of positive FNA. Accuracy of FNA was quantified as the area under the receiver operating characteristic curve with axillary surgery as reference standard.

RESULTS: Of 128 subjects, 61 were positive on FNA and 65 were positive on axillary surgery. Sensitivity, specificity, positive predictive value, and negative predictive value of FNA were 52 of 65 (80%), 54 of 63 (85.7%), 52 of 61(85.2%), and 54 of 67 (80.5%), respectively. After adjusting for neoadjuvant chemotherapy between FNA and surgery, a positive FNA was associated with higher likelihood for positive axillary surgery (odds ratio: 22.7; 95% confidence interval [CI]: 7.2-71.3, P < .0001), and the accuracy of FNA was 0.801 (95% CI: 0.727-0.876). Among ultrasound imaging features, cortical thickness and abnormal hilum were predictive (P < .017) of positive FNA with accuracy of 0.817 (95% CI: 0.741-0.893).

CONCLUSIONS: Ultrasound imaging and FNA can play an important role in the management of early breast cancers even in the post-Z11 era. Higher weightage can be accorded to cortical thickness and hilum during ultrasound evaluation.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Vijayaraghavan GR, Vedantham S, Kataoka M, et al. The Relevance of Ultrasound Imaging of Suspicious Axillary Lymph Nodes and Fine-needle Aspiration Biopsy in the Post-ACOSOG Z11 Era in Early Breast Cancer. Acad Radiol. 2016. PMID: 27916595. doi:10.1016/j.acra.2016.10.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。