通过BI-RADS分类联合剪切波弹性成像对乳腺3类和4类结节的鉴别诊断
研究纳入100例连续女性共126个乳腺病灶(65个良性、61个恶性),用剪切波弹性成像测量结节及结节周围组织的平均杨氏模量(Emean1和Emean2),以病理结果为参考绘制ROC曲线并获得阈值C1和C2,按规则调整BI-RADS分类。BI-RADS联合SWE的AUC、敏感度、特异度分别为0.952、93.4%、95.4%,原始BI-RADS分别为0.883、82.0%、87.7%,差异有统计学意义(p=0.028,Z检验)。
要点
- BI-RADS联合SWE的AUC 0.952、敏感度93.4%、特异度95.4%,原始BI-RADS分别为0.883、82.0%、87.7%(p=0.028,Z检验)。
- Emean1>C1或Emean2>C2时,BI-RADS 3升为4a、4a升为4b;Emean1≤C1且Emean2≤C2时,4b降为4a。
- 本研究将BI-RADS 3和4a视为良性、4b和4c视为恶性。
核心结论
- BI-RADS分类联合SWE测量平均杨氏模量对乳腺结节鉴别诊断有较高价值,有效提高了诊断敏感度和特异度。
研究设计与样本
- 研究纳入100例连续女性共126个乳腺病灶(65个良性、61个恶性),采用剪切波弹性成像测量结节及结节周围组织的平均杨氏模量(Emean1和Emean2),以病理结果为参考标准绘制ROC曲线。
诊断标准与关键数值
- 以病理结果为参考绘制ROC曲线,最高截断值为C1和C2;Emean1>C1或Emean2>C2时BI-RADS 3升为4a、4a升为4b,Emean1≤C1且Emean2≤C2时4b降为4a,其他分类不变。
临床应用与阅片要点
- 阅片时可测量结节及结节周围组织的平均杨氏模量(Emean1和Emean2),按C1、C2阈值调整BI-RADS分类后再判断良恶性(本研究将3和4a视为良性、4b和4c视为恶性)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Ultrasound (US) has become one of the important imaging methods for differentiating benign from malignant breast lesions. In 2013, the American College of Radiology published the fifth edition of the Breast Imaging-Reporting and Data System (BI-RADS). BI-RADS is a guide with recommendations for the standardization of breast imaging (US, mammography and magnetic resonance imaging) reports and for the auditing of centers employing such methods. Its objective is to standardize the nomenclature used in the reports. However, current US examinations are neither adequately sensitive nor sufficiently specific enough. The average Young's modulus was measured through shear wave elastography (SWE) to evaluate the diagnostic value of the BI-RADS classification in conjunction with SWE in differentiating BI-RADS 3 and 4 nodules. A total of 100 consecutive women with 126 breast lesions, including 65 benign and 61 malignant lesions, were included. The average Young's modulus of breast nodules and peri-nodule tissue (Emean1 and Emean2) was also determined through SWE. A receiver operating characteristic curve was drawn on the basis of pathologic results. The highest cut-off values were C1 and C2. At Emean1 > C1 or Emean2 > C2, BI-RADS 3 was increased to 4a and BI-RADS 4a was increased to 4b. At Emean1 ≤ C1 and Emean2 ≤ C2, BI-RADS 4b was decreased to 4a. Other BI-RADS classifications remained unchanged. BI-RADS 3 and 4a were considered benign. BI-RADS 4b and 4c were malignant. The area under the curve, sensitivity and specificity of the BI-RADS classification in conjunction with SWE were 0.952, 93.4% and 95.4%, respectively. The area under the curve, sensitivity and specificity of the original BI-RADS classification were 0.883, 82.0% and 87.7%, respectively. Differences were statistically significant (p = 0.028, Z-test). The diagnostic sensitivity and specificity were increased effectively. As a new method, BI-RADS classification in conjunction with SWE that combines the average Young's modulus yields a high value in terms of the differential diagnosis of breast nodules.
引用
- Wang M, Yang Z, Liu C, et al. Differential Diagnosis of Breast Category 3 and 4 Nodules Through BI-RADS Classification in Conjunction with Shear Wave Elastography. Ultrasound Med Biol. 2016. PMID: 27988221. doi:10.1016/j.ultrasmedbio.2016.10.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。