自动乳腺全容积扫查仪的影像特征与乳腺癌分子亚型的相关性
本研究对303个乳腺恶性肿瘤行自动乳腺全容积扫查(ABVS)观察影像特征,并用免疫组化确定分子亚型,分析两者相关性。单因素分析显示Luminal-A型预测因素为回缩现象(OR=10.188)、后方声影(OR=5.112)和强回声晕(OR=3.263,P<0.001);多因素分析显示回缩现象是Luminal-A型最强的独立预测因素(OR=9.063,P<0.001),其缺失是三阴性型独立预测因素(OR=4.875,P<0.001)。作者认为ABVS影像特征尤其是回缩现象与分子亚型强相关,扩展了超声识别乳腺癌亚型的范围。
要点
- 回缩现象是Luminal-A型最强的独立预测因素(OR=9.063,P<0.001)。
- 回缩现象缺失是三阴性型独立预测因素(OR=4.875,P<0.001)。
- 钙化、非肿块病变、后方回声增强等特征与HER2扩增型相关。
核心结论
- ABVS影像特征尤其是回缩现象与乳腺癌分子亚型强相关,扩展了超声识别乳腺癌亚型的范围。
研究设计与样本
- 研究类型为通过ABVS和免疫组化分析对303个恶性乳腺肿瘤进行影像特征与分子亚型相关性的研究。
- 样本为303个恶性乳腺肿瘤,采用ABVS观察影像特征,免疫组化确定分子亚型。
- 采用单因素和多因素logistic回归分析确定分子亚型的显著预测因素。
关键影像表现/征象
- Luminal-A型(n=128)相关特征包括回缩现象、后方声影和强回声晕。
- HER2扩增型(n=39)相关特征包括钙化、回缩现象缺失、非肿块病变、强回声晕缺失和后方回声增强。
- 三阴性型(n=47)相关特征包括回缩现象缺失、后方回声增强、强回声晕缺失和钙化缺失。
- Luminal-B型(n=89)预测因素关联性相对较低(OR≤2.328)。
诊断标准与关键数值
- 单因素分析Luminal-A型预测因素:回缩现象OR=10.188,后方声影OR=5.112,强回声晕OR=3.263,P<0.001。
- 单因素分析HER2扩增型预测因素:钙化OR=6.210,回缩现象缺失OR=4.375,非肿块病变OR=4.286(P<0.001),强回声晕缺失OR=3.851(P=0.035),后方回声增强OR=3.641(P=0.008)。
- 单因素分析三阴性型预测因素:回缩现象缺失OR=5.884,后方回声增强OR=5.255(P<0.001),强回声晕缺失OR=4.138(P=0.002),钙化缺失OR=3.363(P=0.001)。
- 多因素分析:回缩现象存在时Luminal-A型OR=9.063(P<0.001),回缩现象缺失时三阴性型OR=4.875(P<0.001)。
临床应用与阅片要点
- 阅片时注意观察ABVS上的回缩现象、后方声影、强回声晕、钙化、非肿块病变及后方回声增强等特征。
- 回缩现象的存在提示Luminal-A型可能,其缺失提示三阴性型可能。
- HER2扩增型可能表现为钙化、非肿块病变、强回声晕缺失和后方回声增强。
- Luminal-B型与影像特征的关联性相对较低(OR≤2.328)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the correlation between the imaging features obtained by an automated breast volume scanner (ABVS) and molecular subtypes of breast cancer.
METHODS: We examined 303 malignant breast tumours by ABVS for specific imaging features and by immunohistochemical analysis to determine the molecular subtype. ABVS imaging features, including retraction phenomenon, shape, margins, echogenicity, post-acoustic features, echogenic halo, and calcifications were analysed by univariate and multivariate logistic regression analyses to determine the significant predictive factors of the molecular subtypes.
RESULTS: By univariate logistic regression analysis, the predictive factors of the Luminal-A subtype (n=128) were retraction phenomenon (odds ratio [OR]=10.188), post-acoustic shadowing (OR=5.112), and echogenic halo (OR=3.263, P<0.001). The predictive factors of the Human-epidermal-growth-factor-receptor-2-amplified subtype (n=39) were calcifications (OR=6.210), absence of retraction phenomenon (OR=4.375), non-mass lesions (OR=4.286, P<0.001), absence of echogenic halo (OR=3.851, P=0.035), and post-acoustic enhancement (OR=3.641, P=0.008). The predictors for the Triple-Negative subtype (n=47) were absence of retraction phenomenon (OR=5.884), post-acoustic enhancement (OR=5.255, P<0.001), absence of echogenic halo (OR=4.138, P=0.002), and absence of calcifications (OR=3.363, P=0.001). Predictors for the Luminal-B subtype (n=89) had a relatively lower association (OR≤2.328). By multivariate logistic regression analysis, retraction phenomenon was the strongest independent predictor for the Luminal-A subtype (OR=9.063, P<0.001) when present and for the Triple-Negative subtype (OR=4.875, P<0.001) when absent.
CONCLUSIONS: ABVS imaging features, especially retraction phenomenon, have a strong correlation with the molecular subtypes, expanding the scope of ultrasound in identifying breast cancer subtypes with confidence.
引用
- Zheng FY, Lu Q, Huang BJ, et al. Imaging features of automated breast volume scanner: Correlation with molecular subtypes of breast cancer. Eur J Radiol. 2016. PMID: 28027759. doi:10.1016/j.ejrad.2016.11.032