文献速递妇产影像腹部MR

子宫平滑肌肉瘤与非典型平滑肌瘤的鉴别:定性MR影像特征的诊断准确性及纹理分析的可行性

Differentiation of Uterine Leiomyosarcoma from Atypical Leiomyoma: Diagnostic Accuracy of Qualitative MR Imaging Features and Feasibility of Texture Analysis.
PubMed 文献 · Eur Radiol · 2016-12-05

回顾性纳入41例术前MRI检查的女性(非典型平滑肌瘤22例、平滑肌肉瘤19例),由两名阅片者评估定性MR特征,并对24例(非典型平滑肌瘤14例、平滑肌肉瘤10例)在轴位T2加权图像上分割病灶后行纹理分析。四种定性MR特征与平滑肌肉瘤关联最强;当病灶具备这四种特征中≥3种时,两名阅片者分别达到最高敏感度1.00与0.95、特异度0.95与1.00。纹理分析可行,无监督聚类区分两者的准确度为0.75。

要点

  • 结节状边缘、出血、T2暗区、中央无强化区四种MR特征与平滑肌肉瘤关联最强(每项特征每位阅片者P≤0.0001)。
  • 病灶具备上述四种特征中≥3种时,阅片者1敏感度1.00、特异度0.95,阅片者2敏感度0.95、特异度1.00。
  • 纹理分析在轴位T2加权图像上可行,无监督聚类区分平滑肌肉瘤与非典型平滑肌瘤的准确度为0.75。

核心结论

  • 联合≥3种定性MR特征可准确区分平滑肌肉瘤与非典型平滑肌瘤,纹理分析可行。

研究设计与样本

  • 回顾性研究,纳入41例术前接受MRI检查的女性(非典型平滑肌瘤22例、平滑肌肉瘤19例),由两名阅片者评估定性MR特征;纹理分析纳入24例(非典型平滑肌瘤14例、平滑肌肉瘤10例),在轴位T2加权图像上分割病灶后进行。

关键影像表现/征象

  • 与平滑肌肉瘤关联最强的四种定性MR特征为结节状边缘、出血、T2暗区、中央无强化区(每项特征每位阅片者P≤0.0001)。

诊断标准与关键数值

  • 病灶具备四种特征中≥3种时,阅片者1敏感度1.00(95%CI 0.82-1.00)、特异度0.95(95%CI 0.77-1.00),阅片者2敏感度0.95(95%CI 0.74-1.00)、特异度1.00(95%CI 0.85-1.00)。
  • 纹理分析中16个纹理特征在平滑肌肉瘤与非典型平滑肌瘤间差异显著(P值<0.001-0.036)。
  • 无监督聚类区分平滑肌肉瘤与非典型平滑肌瘤的准确度0.75(敏感度0.70、特异度0.79)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate whether qualitative magnetic resonance (MR) features can distinguish leiomyosarcoma (LMS) from atypical leiomyoma (ALM) and assess the feasibility of texture analysis (TA).

METHODS: This retrospective study included 41 women (ALM = 22, LMS = 19) imaged with MRI prior to surgery. Two readers (R1, R2) evaluated each lesion for qualitative MR features. Associations between MR features and LMS were evaluated with Fisher's exact test. Accuracy measures were calculated for the four most significant features. TA was performed for 24 patients (ALM = 14, LMS = 10) with uniform imaging following lesion segmentation on axial T2-weighted images. Texture features were pre-selected using Wilcoxon signed-rank test with Bonferroni correction and analyzed with unsupervised clustering to separate LMS from ALM.

RESULTS: Four qualitative MR features most strongly associated with LMS were nodular borders, haemorrhage, "T2 dark" area(s), and central unenhanced area(s) (p ≤ 0.0001 each feature/reader). The highest sensitivity [1.00 (95%CI:0.82-1.00)/0.95 (95%CI: 0.74-1.00)] and specificity [0.95 (95%CI:0.77-1.00)/1.00 (95%CI:0.85-1.00)] were achieved for R1/R2, respectively, when a lesion had ≥3 of these four features. Sixteen texture features differed significantly between LMS and ALM (p-values: <0.001-0.036). Unsupervised clustering achieved accuracy of 0.75 (sensitivity: 0.70; specificity: 0.79).

CONCLUSIONS: Combination of ≥3 qualitative MR features accurately distinguished LMS from ALM. TA was feasible.

KEY POINTS: • Four qualitative MR features demonstrated the strongest statistical association with LMS. • Combination of ≥3 these features could accurately differentiate LMS from ALM. • Texture analysis was a feasible semi-automated approach for lesion categorization.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lakhman Y, Veeraraghavan H, Chaim J, et al. Differentiation of Uterine Leiomyosarcoma from Atypical Leiomyoma: Diagnostic Accuracy of Qualitative MR Imaging Features and Feasibility of Texture Analysis. Eur Radiol. 2016. PMID: 27921159. doi:10.1007/s00330-016-4623-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。