文献速递腹部泌尿生殖CTDR

CTKUB检出结石时替代基线KUB的方案:CT定位像与平均及最大密度投影图像评估

Alternatives to the baseline KUB for CTKUB-detected calculi: evaluation of CT scout and average and maximum intensity projection images.
PubMed 文献 · Abdom Radiol (NY) · 2017-01-01

本研究回顾性分析74枚结石,比较KUB、CT定位像、厚层平均密度投影(AIP)和最大密度投影(MIP)对结石的显示敏感度及一致性。MIP敏感度83.8%最高,KUB 66.2%,AIP 55.4%,CT定位像47.3%;各替代方案与KUB仅呈一般至中等一致性,未发现结石特征或患者厚度与不一致结果显著相关。

要点

  • MIP对结石的敏感度(83.8%)高于KUB(66.2%)、AIP(55.4%)和CT定位像(47.3%)。
  • MIP与KUB一致性为中等(κ=0.412),CT定位像和AIP与KUB一致性均为一般(κ=0.363、0.384)。
  • 未发现结石大小、位置、峰值HU或患者厚度与结果不一致显著相关。

核心结论

  • 所有可能的基线KUB替代方案与KUB的一致性均不强;低剂量CT定位像的敏感度与已发表文献中较高剂量CT定位像相似。

研究设计与样本

  • 回顾性研究,纳入一家三级成人机构中CTKUB阳性且CT后4小时内行KUB的患者,共评估74枚结石;由两名顾问放射科医师独立阅片,比较KUB、CT定位像、AIP和MIP的结石显示敏感度及一致性。

关键影像表现/征象

  • CT定位像对结石的敏感度为47.3%(95%CI 35.6-59.3)。
  • 厚层AIP对结石的敏感度为55.4%(95%CI 43.4-67.0)。
  • MIP对结石的敏感度为83.8%(95%CI 73.4-91.3)。
  • KUB对结石的敏感度为66.2%(95%CI 54.3-76.8)。

诊断标准与关键数值

  • KUB与CT定位像一致性一般:κ=0.363(95%CI 0.167-0.558)。
  • KUB与AIP一致性一般:κ=0.384(95%CI 0.175-0.592)。
  • KUB与MIP一致性中等:κ=0.412(95%CI 0.198-0.625)。
  • 未发现结石特征(大小、位置、峰值HU)或患者厚度与不一致结果有显著关联。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: A CT of the kidneys, ureters, and bladder (CTKUB) is the investigation of choice in suspected renal colic. Plain kidney, ureter, and bladder radiographs (KUB) can be used to monitor the progress of a stone if radiographically visible on a baseline KUB. This study aims to determine if a low-dose CT Scout, thick-slab average intensity projection (AIP), or maximum intensity projection (MIP) images are suitable as substitutes for a baseline KUB.

METHOD: A retrospective review of patients from a tertiary adult institute that had a positive CTKUB and a KUB within 4 h of the CT was performed. Two consultant radiologists independently reviewed the KUB, CT Scout, AIP, and MIP for stone visibility and their sensitivities and agreement values were compared. Stone characteristics (size, location, and peak Hounsfield units) and patient thickness were recorded and examined for any association with discordant results.

RESULTS: 74 stones were evaluated for the study. KUB had a sensitivity of 66.2% (95% CI 54.3-76.8), CT Scout 47.3% (95% CI 35.6-59.3), AIP 55.4% (95% CI 43.4-67.0), and MIP 83.8% (95% CI 73.4-91.3). Fair agreement was found between the KUB and both CT Scout (κ=0.363, 95% CI 0.167-0.558) and AIP (κ=0.384, 95% CI 0.175-0.592). Moderate agreement was found between the KUB and MIP (κ=0.412, 95% CI 0.198-0.625). Neither any stone characteristic nor patient thickness had a significant association with discordant results.

CONCLUSION: None of the possible substitutes for a baseline KUB showed strong agreement with the KUB. Low-dose CT Scouts have a similar sensitivity to the published literature for higher dose CT Scouts.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Lew HM, Seow JH, Hewavitharana CP, et al. Alternatives to the baseline KUB for CTKUB-detected calculi: evaluation of CT scout and average and maximum intensity projection images. Abdom Radiol (NY). 2017. PMID: 27933480. doi:10.1007/s00261-016-1003-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。