中段尿道吊带置入后下尿路症状女性的经会阴超声与尿动力学表现
回顾性分析77例中段尿道吊带置入后出现下尿路症状女性的经会阴动态二维超声与尿动力学检查,按吊带静息至最大Valsalva动作的形态变化分为3组。第3组最大尿流率时逼尿肌压力显著高于第1、2组(36±16 vs 19±11 mm H₂O,P<.001),多因素校正后第3组与高逼尿肌压力独立相关(OR 29.7,95%CI 2.949-299.6,P=.0040)。经会阴动态二维超声可能有助于预测吊带术后高压排尿并辅助诊断膀胱出口梗阻。
要点
- 吊带静息即呈C形且Valsalva时维持C形(第3组)与高逼尿肌压力相关。
- 第3组最大尿流率时逼尿肌压力均值36±16 mm H₂O,高于第1、2组的19±11 mm H₂O。
- 动态经会阴超声可观察吊带从静息到最大Valsalva再回静息的形态变化。
核心结论
- 经会阴动态二维超声可能有助于预测中段尿道吊带置入后出现高压排尿的女性,并辅助诊断膀胱出口梗阻。
研究设计与样本
- 研究类型为回顾性分析(原文未明确写回顾性,但原文为reviewed from women,按原文照录为对经会阴盆腔超声和尿动力学检查进行复习);样本量77例女性;设备为动态二维经会阴盆腔超声;参考标准为尿动力学检查;分组依据为吊带静息至最大Valsalva动作的形态变化分为3组。
关键影像表现/征象
- 第1组:静息时吊带平行于尿道腔,Valsalva时吊带呈C形。
- 第2组:静息和Valsalva时吊带均平行于尿道腔。
- 第3组:静息时吊带呈C形,Valsalva时维持该弯曲形态。
诊断标准与关键数值
- 最大尿流率时逼尿肌压力:第3组均值36±16 mm H₂O vs 第1、2组19±11 mm H₂O,P<.001。
- 高逼尿肌压力定义为>20 mm H₂O;第3组发生高逼尿肌压力的比值约为第1、2组的12倍。
- 多因素logistic回归校正其他变量后,第3组与高逼尿肌压力独立相关:OR 29.7(95%CI 2.949-299.6),P=.0040。
临床应用与阅片要点
- 经会阴动态二维超声可观察吊带静息至最大Valsalva动作的形态变化并据此分组。
- 第3组形态(静息C形且Valsalva时维持C形)与高逼尿肌压力相关,可能辅助识别高压排尿。
- 作者认为经会阴动态二维超声可能有助于预测吊带术后高压排尿并辅助诊断膀胱出口梗阻。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate dynamic 2-dimensional (2D) transperineal pelvic sonographic findings and urodynamic studies in women with lower urinary tract symptoms after midurethral sling placement.
METHODS: Transperineal pelvic sonography and urodynamic studies were reviewed from women with a midurethral sling and lower urinary tract symptoms. The shape and sonographic dynamic change of the sling from the rest position to the maximum Valsalva maneuver and back to rest were recorded. Patients were categorized into 3 groups: group I, at rest, the sling lies parallel to the urethral lumen, and during Valsalva, the sling becomes C shaped; group 2, both at rest and during Valsalva, the sling runs parallel to the urethral lumen; and group 3, at rest, the sling is C shaped, and during Valsalva, this curved shape is maintained. For analytical purposes group 3 was compared with groups 1 and 2. Multiple logistic regressions were used to evaluate the association between transperineal pelvic sonography and urodynamic studies.
RESULTS: Seventy-seven women were enrolled. The detrusor pressure at the maximum flow rate was significantly higher in group 3 than groups 1 and 2 (mean ± SD, 36 ± 16 versus 19 ± 11 mm H2 O; P < .001). The odds of high detrusor pressure (>20 mm H2 O) in group 3 was approximately 12 times the odds of those in groups 1 and 2. After adjusting for other variables using a multiple logistic regression analysis, a statistically significant association between group 3 and high detrusor pressure persisted (odds ratio, 29.7; 95% confidence interval, 2.949-299.6; P = .0040) persisted.
CONCLUSIONS: Transperineal dynamic 2D sonography can help predict women with high-pressure voiding after midurethral sling placement and aid in the diagnosis of bladder outlet obstruction.
引用
- Takacs P, Larson K, Scott L, et al. Transperineal Sonography and Urodynamic Findings in Women With Lower Urinary Tract Symptoms After Sling Placement. J Ultrasound Med. 2016. PMID: 27925696. doi:10.7863/ultra.16.02076
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。