超声能否用于评估站立位不同静态手臂位置下的深层腹部肌肉激活
本研究在站立位4种静态手臂位置下对腹横肌和腹内斜肌行超声记录,每位置重复10次非连续测量并在每块肌肉2个位置测厚。结果显示两肌厚度测量可靠性高,腹横肌在肩屈曲时较肩伸展或手臂过头时更厚,腹内斜肌各手臂位置间厚度无差异;结合既往肌电数据,作者对以厚度替代肌肉激活的效度提出担忧。
要点
- 站立位不同静态手臂位置下,超声测量腹横肌与腹内斜肌厚度可靠性高。
- 腹横肌在肩屈曲位较肩伸展或手臂过头位更厚,肩伸展位较手臂自然下垂位更薄。
- 腹内斜肌各手臂位置间厚度无显著差异,厚度替代激活的效度存疑。
核心结论
- 站立位不同静态手臂位置下超声记录腹内斜肌和腹横肌可提供可靠的肌肉厚度测量,但结合既往肌电数据,以厚度测量作为肌肉激活替代指标在可能引起被动肌肉形变的位置上效度存疑。
研究设计与样本
- 方法学研究,10名受试者,在站立位4种静态手臂位置下对腹横肌和腹内斜肌行超声记录,每位置10次非连续重复,每块肌肉2个位置测厚;可靠性用泛化理论分析,厚度比较用重复测量方差分析,筋膜滑动用单样本t检验。
诊断标准与关键数值
- 腹横肌厚度:肩屈曲位较肩伸展位或手臂过头位更厚(P < .021),手臂自然下垂位较肩伸展位更厚(P < .005);腹内斜肌各手臂位置间厚度无差异(P = .059)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 结合既往肌电数据,结果对以厚度测量替代肌肉激活的效度提出担忧,尤其是在可能引起被动肌肉形变的位置。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to investigate whether sonography is a reliable tool for measuring deep abdominal muscle activation in different static arm positions while standing.
METHODS: Sonographic recordings were made of the transversus abdominis and obliquus internus abdominis in 4 different static arm positions that varied with regard to the postural demand and loading direction posed on the trunk. Ten nonconsecutive repetitions of each arm position were performed, and thickness measurements were made at 2 locations within each muscle. Reliability was analyzed by the generalizability theory; comparisons regarding thickness measurements were made by repeated-measures analyses of variance; and fascial sliding was analyzed by a 1-sample t test.
RESULTS: Averaged over all repetitions, arm positions, and the 2 measurement locations, the thickness measurements were highly reliable for both the obliquus internus abdominis and transversus abdominis. The transversus abdominis was thicker with shoulders flexed than with shoulders extended or arms above the head (P < .021) and with arms alongside the body compared with shoulders extended (P < .005). There was no thickness difference between arm positions for the obliquus internus abdominis (P = .059).
CONCLUSIONS: The results indicate that sonographic recordings of the obliquus internus abdominis and transversus abdominis in different static arm positions while standing provide reliable measurements of muscle thickness. However, in light of previously reported electromyographic data, the results raise some concerns regarding the validity of using thickness measurements as proxies for muscle activation in positions that may induce passive muscle deformation.
引用
- Eriksson Crommert M, Unsgaard-Tøndel M, Vasseljen O, et al. Can Sonography Be Used to Estimate Deep Abdominal Muscle Activation in Different Static Arm Positions While Standing? J Ultrasound Med. 2016. PMID: 27914181. doi:10.7863/ultra.15.12057
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。