超声狭窄指数:一种新的移植肝动脉狭窄特异性定量指标
本研究回顾性分析69例疑似移植肝动脉狭窄(THAS)患者,评估基于全频谱多普勒波形计算的狭窄指数(SI)检测THAS的敏感度和特异度,并与阻力指数(RI)和搏动指数(PI)比较。结果显示SI的AUC为0.86,显著高于RI(0.68)和PI(0.70);SI<1.35时敏感度94%、特异度52%。结论认为SI比RI和PI更准确。
要点
- SI计算基于频谱多普勒高频与低频信号曲线下面积之比。
- SI检测THAS的AUC为0.86,显著高于RI(0.68)和PI(0.70)。
- SI<1.35时敏感度94%、特异度52%;RI<0.5时敏感度96%、特异度29%。
核心结论
- 狭窄指数(SI)检测移植肝动脉狭窄的准确度高于阻力指数(RI)和搏动指数(PI)。
研究设计与样本
- 经机构审查委员会批准、符合HIPAA的回顾性研究,纳入2006年1月至2010年12月间因疑似移植肝动脉狭窄行导管血管造影的69例患者,所有患者造影前30天内均行多普勒超声;以造影狭窄需干预为THAS阳性。
诊断标准与关键数值
- SI由频谱多普勒中高频信号与低频信号曲线下面积之比计算。
- THAS组SI=1.04±0.20,无THAS组SI=1.39±0.30,组间差异P<.001。
- SI检测THAS的AUC为0.86,显著高于RI(AUC=0.68,P=.038)和PI(AUC=0.70,P=.029)。
- SI<1.35时检测THAS的敏感度94%、特异度52%;RI<0.5时敏感度96%、特异度29%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study evaluates the sensitivity and specificity of stenosis index (SI), which accounts for the entire spectral Doppler waveform, to detect significant transplant hepatic arterial stenosis.
MATERIALS AND METHODS: In this institutional review board-approved, HIPAA compliant study, we retrospectively analyzed 69 patients who had catheter angiography for suspected transplant hepatic arterial stenosis (THAS) between January 2006 and December 2010; all patients had Doppler ultrasound within 30 days before angiography. Patients with angiographic stenosis requiring intervention were considered positive for THAS. Stenosis index was calculated from each patient's spectral Doppler ultrasound images by obtaining the ratio of the area under the high-frequency signal to low-frequency signal in the spectral Doppler. Resistive index (RI) and pulsatility index (PI) were also calculated. Receiver operator curve analysis was performed and the area under the curve (AUC) was compared among the three metrics.
RESULTS: Forty-eight of 69 patients had THAS by angiography requiring intervention; 21patients had no angiographic evidence of THAS. SI was significantly different (P < .001) between patients with THAS (SI = 1.04 ± 0.20) and those without THAS (SI = 1.39 ± 0.30). Stenosis index had an AUC of 0.86 for detecting THAS, which was significantly higher than that from RI (AUC = 0.68, P = .038 for the comparison) and PI (AUC = 0.70, P = .029). For SI < 1.35, the sensitivity for THAS was 94% and specificity was 52%. For RI < 0.5, the sensitivity was 96% and the specificity was 29%.
CONCLUSIONS: Stenosis index is more accurate than the resistive index and the pulsatility index for detecting transplant hepatic artery stenosis.
引用
- Le TX, Hippe DS, McNeeley MF, et al. The Sonographic Stenosis Index: A New Specific Quantitative Measure of Transplant Hepatic Arterial Stenosis. J Ultrasound Med. 2016. PMID: 28029703. doi:10.7863/ultra.16.01005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。