文献速递腹部技术与安全US

二维剪切波弹性成像无创评估慢性乙型肝炎患者肝纤维化的性能:与血清纤维化指标的对比

Two-dimensional Shear-Wave Elastography Performance in the Noninvasive Evaluation of Liver Fibrosis in Patients with Chronic Hepatitis B: Comparison with Serum Fibrosis Indexes.
PubMed 文献 · Radiology · 2016-12-13

研究纳入2015年7月至2016年5月接受部分肝切除术的539例慢性乙型肝炎患者,按Scheuer系统以切除肝标本分组,比较二维剪切波弹性成像与血清纤维化模型(APRI、FIB-4、King评分、Forns指数)的诊断性能。二维剪切波弹性成像诊断显著纤维化、严重纤维化和肝硬化的AUC分别为0.97、0.97和0.98,显著高于血清模型(P < .05)。

要点

  • 二维剪切波弹性成像诊断显著纤维化(≥S2)、严重纤维化(≥S3)和肝硬化(S4)的AUC分别为0.97、0.97和0.98。
  • 肝硬度最佳截断值:≥S2为7.6 kPa,≥S3为9.2 kPa,S4为10.4 kPa。
  • 验证队列中各无创方法评估不同纤维化分期的AUC与指数队列无显著差异。

核心结论

  • 二维剪切波弹性成像方案可用于预测慢性乙型肝炎患者的显著纤维化、严重纤维化和肝硬化,诊断准确性显著高于血清纤维化模型。

研究设计与样本

  • 经伦理委员会批准并获知情同意的研究,2015年7月至2016年5月纳入539例接受部分肝切除术者,按切除肝标本的Scheuer系统分组。

诊断标准与关键数值

  • 指数队列中,与显著纤维化(≥S2)相关的最佳肝硬度截断值为7.6 kPa,AUC为0.97。
  • 指数队列中,与严重纤维化(≥S3)相关的最佳肝硬度截断值为9.2 kPa,AUC为0.96。
  • 指数队列中,与肝硬化(S4)相关的最佳肝硬度截断值为10.4 kPa,AUC为0.98。
  • 诊断显著纤维化时,APRI、FIB-4、King评分和Forns指数的AUC分别为0.77、0.73、0.79和0.77。
  • 诊断肝硬化时,APRI、FIB-4、King评分和Forns指数的AUC分别为0.70、0.71、0.72和0.74。

临床应用与阅片要点

  • 二维剪切波弹性成像诊断显著纤维化、严重纤维化和肝硬化的AUC分别为0.97、0.97和0.98,显著高于血清模型(P < .05)。
  • 二维剪切波弹性成像、APRI、FIB-4、King评分和Forns指数均与肝纤维化分期显著相关(ρ分别为0.88、0.41、0.40、0.43和0.45;P < .05)。
  • 验证队列中各无创方法评估不同纤维化分期的AUC与指数队列无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To investigate the value of two-dimensional (2D) shear-wave elastography (SWE) in the assessment of hepatic fibrosis in patients with chronic hepatitis B (CHB) and to compare the diagnostic performance of this modality with that of liver fibrosis indexes. Materials and Methods The ethics committee approved this study, and informed consent was obtained. From July 2015 to May 2016, 539 subjects who underwent partial hepatectomy were divided into groups according to the Scheuer system by using a resected liver specimen. All patients were examined with 2D SWE and underwent preoperative serologic testing to measure liver stiffness and values of serum fibrosis models, which were compared with histologic findings. Performance of noninvasive methods was determined for index (304 patients) and validation (155 patients) cohorts by using areas under the receiver operating characteristic curve (AUCs). Results For association with substantial fibrosis (≥S2), severe fibrosis (≥S3), and cirrhosis (S4) in the index cohort, the optimal cutoff values of liver stiffness were 7.6, 9.2, and 10.4 kPa, respectively, and AUC values were 0.97, 0.96, and 0.98, respectively. The 2D SWE findings, aspartate transaminase-to-platelet ratio index (APRI), fibrosis index based on the four factors (FIB-4), King's score, and Forns index significantly correlated with hepatic fibrosis stages (ρ = 0.88, ρ = 0.41, ρ = 0.40, ρ = 0.43 and ρ = 0.45, respectively; P < .05). The AUCs for APRI, FIB-4, King's score, and Forns index were 0.77, 0.73, 0.79, and 0.77, respectively, in the diagnosis of substantial fibrosis and 0.70, 0.71, 0.72, and 0.74, respectively, in the diagnosis of cirrhosis. In the validation cohort, AUCs of noninvasive methods used to assess different fibrosis stages did not significantly differ from those for the index cohort. AUCs of 2D SWE in the diagnosis of substantial fibrosis, severe fibrosis, and cirrhosis were 0.97, 0.97, and 0.98, respectively, which were significantly higher than those in serum models (P < .05). Conclusion The 2D SWE protocol could be used to predict substantial fibrosis, severe fibrosis, and cirrhosis in patients with CHB with notably higher diagnostic accuracy than that attained with serum fibrosis models. © RSNA, 2016.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Zhuang Y, Ding H, Zhang Y, et al. Two-dimensional Shear-Wave Elastography Performance in the Noninvasive Evaluation of Liver Fibrosis in Patients with Chronic Hepatitis B: Comparison with Serum Fibrosis Indexes. Radiology. 2016. PMID: 27982760. doi:10.1148/radiol.2016160131

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。