钆塞酸二钠与翻转角对3T六回波梯度回波幅度法MR成像肝脏质子密度脂肪分数估计的影响
前瞻性纳入31例已知或疑似肝脂肪变性成人,在3T临床钆塞酸二钠增强肝脏MRI中比较低翻转角(10°)与高翻转角(50°)在增强前后对基于幅度法的多梯度回波MRI质子密度脂肪分数估计准确性的影响,以MR波谱为参考标准。结果显示增强后高翻转角序列在整体及低PDFF范围内的回归偏倚最接近0,准确性最高,且相比其他序列在至少两个回归参数上有统计学显著改善。
要点
- 增强后高翻转角序列在整体及低PDFF范围内回归偏倚最接近0,准确性最高。
- 增强前高翻转角MRI会随MRS-PDFF成比例高估PDFF,整体斜率为0.72,低PDFF范围为0.63。
- 增强前低翻转角、增强后低翻转角和增强后高翻转角三个序列整体及低PDFF范围估计相对无偏。
核心结论
- 在钆塞酸二钠增强MR检查中,增强后图像使用高翻转角可提高基于幅度法多梯度回波MRI的PDFF估计准确性。
研究设计与样本
- 前瞻性研究,纳入31例已知或疑似肝脂肪变性的成人,在3T临床钆塞酸二钠增强肝脏MRI中,以增强前MR波谱测得的MRS-PDFF为参考标准,比较增强前后低翻转角(10°)与高翻转角(50°)MRI-M序列的PDFF估计。
诊断标准与关键数值
- 以MR波谱测得的MRS-PDFF为参考标准;线性回归参数包括斜率、截距、平均偏倚和R²;增强前高翻转角MRI整体斜率为0.72、低PDFF范围斜率为0.63;增强后高翻转角序列回归偏倚最接近0,在整体及低PDFF范围准确性最高,且相比其他每个序列在至少两个回归参数上有统计学显著改善。
临床应用与阅片要点
- 在钆塞酸二钠增强肝脏MRI中,基于幅度法多梯度回波MRI估计PDFF时,增强后图像采用高翻转角(50°)可提高准确性;增强前高翻转角图像会随MRS-PDFF成比例高估PDFF。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of the study was to determine in patients undergoing gadoxetate disodium (Gx)-enhanced MR exams whether proton density fat fraction (PDFF) estimation accuracy of magnitude-based multi-gradient-echo MRI (MRI-M) could be improved by using high flip angle (FA) on post-contrast images.
MATERIALS AND METHODS: Thirty-one adults with known or suspected hepatic steatosis undergoing 3T clinical Gx-enhanced liver MRI were enrolled prospectively. MR spectroscopy (MRS), the reference standard, was performed before Gx to measure MRS-PDFF. Low (10°)- and high (50°)-flip angle (FA) MRI-M sequences were acquired before and during the hepatobiliary phase after Gx administration; MRI-PDFF was estimated in the MRS-PDFF voxel location. Linear regression parameters (slope, intercept, average bias, R 2) were calculated for MRS-PDFF as a function of MRI-PDFF for each MRI-M sequence (pre-Gx low-FA, pre-Gx high-FA, post-Gx low-FA, post-Gx high-FA) for all patients and for patients with MRS-PDFF <10%. Regression parameters were compared (Bonferroni-adjusted bootstrap-based tests).
RESULTS: Three of the four MRI-M sequences (pre-Gx low-FA, post-Gx low-FA, post-Gx high-FA) provided relatively unbiased PDFF estimates overall and in the low-PDFF range, with regression slopes close to 1 and intercepts and biases close to zero. Pre-Gx high-FA MRI overestimated PDFF in proportion to MRS-PDFF, with slopes of 0.72 (overall) and 0.63 (low-PDFF range). Based on regression bias closest to 0, the post-Gx high-FA sequence was the most accurate overall and in the low-PDFF range. This sequence provided statistically significant improvements in at least two regression parameters compared to every other sequence.
CONCLUSION: In patients undergoing Gx-enhanced MR exams, PDFF estimation accuracy of MRI-M can be improved by using high-FA on post-contrast images.
引用
- Park CC, Hamilton G, Desai A, et al. Effect of intravenous gadoxetate disodium and flip angle on hepatic proton density fat fraction estimation with six-echo, gradient-recalled-echo, magnitude-based MR imaging at 3T. Abdom Radiol (NY). 2017. PMID: 28028556. doi:10.1007/s00261-016-0992-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。