采用改良LI-RADS算法提高肝细胞癌诊断的阅片者间一致性
该研究回顾性纳入84例肝硬化患者的104个肝脏病灶,以病理和影像随访为标准,比较标准LI-RADS v2014与改良LI-RADS(mLI-RADS)对LR3-5病灶的分类。两种算法诊断性能相同(AUC=0.91),但mLI-RADS的阅片者间一致性更高(总体κ=0.53±0.04 vs 0.45±0.04),且评估时间更短(中位51秒 vs 62秒,p<0.0001)。
要点
- 改良LI-RADS聚焦病灶大小和廓清标准,简化LR3-5决策树。
- mLI-RADS与标准LI-RADS诊断性能相同(AUC=0.91)。
- mLI-RADS总体阅片者间一致性更高(κ=0.53±0.04 vs 0.45±0.04)。
核心结论
- 聚焦病灶大小和廓清标准的改良阶梯式LI-RADS决策树用于LR3-5病灶,可在保持诊断准确性的同时提高阅片者间信度并加快分类速度。
研究设计与样本
- 回顾性研究,纳入84例肝硬化患者的104个肝脏病灶,以组织病理学和影像随访为标准,由4名独立放射科医师分别按LI-RADS v2014和改良LI-RADS分类并计时。
诊断标准与关键数值
- LI-RADS与mLI-RADS的ROC曲线下面积均为0.91;mLI-RADS总体κ=0.53±0.04,标准LI-RADS总体κ=0.45±0.04;多数阅片者两两间κ范围mLI-RADS 0.44-0.62 vs 标准LI-RADS 0.35-0.60。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate a simplified Liver Imaging Reporting and Data System (LI-RADS) algorithm to improve interreader agreement while maintaining diagnostic performance for HCC.
MATERIALS AND METHODS: MRI scans of 84 cirrhotic patients with 104 distinct liver observations were retrospectively selected to equivocally match each of the LI-RADS grades (LR1-5) using histopathology and imaging follow up as standard of reference. Four independent radiologists categorized all observations as benign (LR1-2) or potentially malignant (LR3-5) and determined LI-RADS based imaging features including observation size, arterial phase hyperenhancement, washout, capsule appearance and threshold growth for LR3-5 observations and timed their readouts. LR3-5 observations were categorized according to the LI-RADS v2014 algorithm and according to a modified LI-RADS (mLI-RADS) version. Diagnostic performance and Interreader agreement were determined for LI-RADS and mLI-RADS using receiver operating characteristics (ROC) and Fleiss' and Cohen's Kappa analysis respectively.
RESULTS: ROC analysis revealed equal diagnostic performance for LI-RADS and mLI-RADS (area under the ROC curve=0.91). Interreader agreement was higher using mLI-RADS as compared to current LI-RADS showing an improved overall (κ=0.53±0.04 vs. 0.45±0.04), and pair-wise agreement between most readers (κ range 0.44-0.62 vs. 0.35-0.60) at a reduced median evaluation time (51 vs. 62s per observation, p<0.0001).
CONCLUSION: Focusing on observation size and washout criteria using a modified, stepwise LI-RADS decision tree for LR3-5 observations results in higher interobserver reliability and faster categorization while maintaining diagnostic accuracy.
引用
- Becker AS, Barth BK, Marquez PH, et al. Increased interreader agreement in diagnosis of hepatocellular carcinoma using an adapted LI-RADS algorithm. Eur J Radiol. 2016. PMID: 28027763. doi:10.1016/j.ejrad.2016.11.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。