肝脏时间谐波弹性成像对肝内压力梯度及经颈静脉肝内门体分流术(TIPS)植入后肝脏减压敏感
前瞻性研究10例伴腹水的肝硬化门脉高压患者,TIPS植入前后行有创HVPG测量和多频时间谐波超声弹性成像(THE)测肝脏剪切波速度(SWS)。TIPS后HVPG从20.4±2.2 mmHg降至9.8±4.1 mmHg,SWS从3.87±0.54 m/s降至3.27±0.44 m/s,HVPG平均降低-10.6±3.7 mmHg(p<0.001),SWS平均降低-0.60±0.29 m/s(p<0.001),HVPG与SWS呈线性相关(R=0.59,p=0.0061)。
要点
- TIPS后HVPG从20.4±2.2 mmHg降至9.8±4.1 mmHg,平均降低-10.6±3.7 mmHg(p<0.001)。
- THE测得SWS从3.87±0.54 m/s降至3.27±0.44 m/s,平均降低-0.60±0.29 m/s(p<0.001)。
- HVPG与SWS呈线性相关(R=0.59,p=0.0061)。
核心结论
- THE测得的SWS是TIPS后肝脏减压的首个潜在直接超声标志物,可能适用于无创检测门脉高压。
研究设计与样本
- 前瞻性研究,纳入10例伴腹水的肝硬化门脉高压患者,TIPS植入前后行有创HVPG测量和多频时间谐波超声弹性成像(THE)测肝脏SWS。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
We investigated the correlation between hepatic venous pressure gradient (HVPG) and liver shear wave speed (SWS) measured by multi-frequency time-harmonic ultrasound elastography (THE) before and after transjugular intrahepatic portosystemic shunt (TIPS) implantation. Ten patients with ascites, cirrhotic liver disease and portal hypertension were prospectively examined with invasive HVPG measurement and THE before and after TIPS implantation. HVPG and SWS decreased after TIPS placement from 20.4 ± 2.2 mmHg to 9.8 ± 4.1 mmHg (mean ± standard deviation) and from 3.87 ± 0.54 m/s to 3.27 ± 0.44 m/s. Mean reduction HVPG was -10.6 ± 3.7 mmHg, p < 0.001; mean reduction SWS was -0.60 ± 0.29 m/s, p < 0.001. A linear correlation was observed between HVPG and SWS (R = 0.59, p = 0.0061). THE-measured SWS is a first potential direct ultrasound marker for liver decompression following TIPS in ascites-associated cirrhotic liver disease and therefore might be suitable to non-invasively detect portal hypertension.
引用
- Tzschätzsch H, Sack I, Marticorena Garcia SR, et al. Time-Harmonic Elastography of the Liver is Sensitive to Intrahepatic Pressure Gradient and Liver Decompression after Transjugular Intrahepatic Portosystemic Shunt (TIPS) Implantation. Ultrasound Med Biol. 2016. PMID: 27979668. doi:10.1016/j.ultrasmedbio.2016.10.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。