肝切除术后肝衰竭:术前剪切波弹性成像技术风险评估
前瞻性纳入80例连续接受肝切除术的肝细胞癌患者,术前用剪切波弹性成像测量肝硬度。多因素分析显示SWE值升高(P=0.002)和组织学肝硬化(P=0.003)是肝切除术后肝衰竭的独立预测因素。SWE≥6.9 kPa预测肝衰竭的AUC为0.843,敏感度77.8%,特异度78.0%。
要点
- SWE≥6.9 kPa者肝切除术后肝衰竭风险更高,AUC 0.843,敏感度77.8%,特异度78.0%。
- SWE值升高(P=0.002)和组织学肝硬化(P=0.003)是肝切除术后肝衰竭的独立预测因素。
- SWE<6.9 kPa者术后MELD评分中位数动态逐渐下降,SWE>6.9 kPa者MELD评分中位数动态呈不规则变化。
核心结论
- SWE测量的肝硬度是预测肝细胞癌患者肝切除术后ISGLS分级A/B级肝衰竭的有效可靠方法。
- SWE可能成为术前评估肝切除术后肝衰竭的常规检查。
研究设计与样本
- 前瞻性识别并评估80例连续接受肝切除术的肝细胞癌患者,术前行SWE检查。
- SWE使用先进超声设备(Philips EPIQ7;Philips Healthcare,西雅图,华盛顿州,美国)测量。
- 肝切除术后肝衰竭按国际肝脏外科研究组建议(ISGLS)分级。
诊断标准与关键数值
- SWE成功完成于77例患者。
- 按ISGLS标准,肝切除术后肝衰竭发生于35.1%的患者(27例),其中Grade A/B分别为2/25例。
- SWE值≥6.9 kPa者肝切除术后肝衰竭风险更高,AUC 0.843,敏感度77.8%,特异度78.0%。
临床应用与阅片要点
- 作者认为,SWE测量的肝硬度可用于预测肝细胞癌患者肝切除术后ISGLS分级A/B级肝衰竭。
- 作者认为,SWE可能成为术前评估肝切除术后肝衰竭的常规检查。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine the efficacy of liver stiffness (LS) measurements utilizing the Shear Wave Elastography (SWE) technique for predicting post-hepatectomy liver failure (PHLF) among patients with hepatocellular carcinoma (HCC).
METHODS: Data from eighty consecutive patients who were undergoing hepatectomy for HCC were prospectively identified and evaluated with preoperative SWE. The SWE was measured with advanced ultrasound equipment (Philips EPIQ7; Philips Healthcare, Seattle, WA, USA). PHLF classification was defined according to the International Study Group of Liver Surgery Recommendations (ISGLS).
RESULTS: SWE was successfully performed in 77 patients. According to the ISGLS criteria, PHLF occurred in 35.1% of patients (27 patients), including 2/25 patients with Grade A/B, respectively. Elevated SWE values (P=0.002) and histological cirrhosis (P=0.003) were independent predictors of PHLF according to the multivariate analysis. Patients with SWE values higher than or equal to 6.9kPa were identified at higher risk of PHLF (area under the curve: 0.843, sensitivity: 77.8% and specificity: 78.0%). Postoperative dynamic course of the median the Model For End-stage Liver Disease (MELD) score showed irregular changes among patients with an SWE >6.9kPa. Patients with an SWE <6.9kPa, postoperative dynamic course of the median MELD score gradually decreased.
CONCLUSION: LS measured with SWE is a valid and reliable method for the prediction of PHLF grade A/B among patients with HCC. SWE could become a routine examination for the preoperative evaluation of PHLF.
引用
- Han H, Hu H, Xu YD, et al. Liver failure after hepatectomy: A risk assessment using the pre-hepatectomy shear wave elastography technique. Eur J Radiol. 2016. PMID: 28027753. doi:10.1016/j.ejrad.2016.11.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。