文献速递腹部技术与安全CT

噪声优化虚拟单能双能CT:胃肠道间质瘤患者中千电子伏特设置优化

Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors.
PubMed 文献 · Abdom Radiol (NY) · 2017-01-01

本研究对21例胃肠道间质瘤(GIST)患者的45组腹部双能CT数据,分别用标准线性融合(M_0.6)、噪声优化虚拟单能(VMI+)和传统虚拟单能(VMI)算法以10 keV为间隔从40至100 keV重建。40 keV VMI+的SNR和CNR最高,显著优于线性融合和所有VMI系列(均P<0.001);60 keV VMI+的整体图像质量和锐利度最佳。结论认为低keV VMI+可显著提高GIST的SNR和CNR并改善图像质量。

要点

  • 40 keV VMI+的SNR 27.8±13.0、CNR 26.3±12.7,显著高于线性融合(SNR 16.8±7.3;CNR 13.6±6.9)及所有VMI系列(均P<0.001)。
  • 整体图像质量和图像锐利度在60 keV VMI+最高(中位数均为5,P≤0.023)。
  • 病变轮廓显示在40和50 keV VMI+最佳(中位数均为5),图像噪声在90和100 keV的VMI和VMI+最佳(中位数均为5)。

核心结论

  • 低keV VMI+重建较传统VMI和标准线性融合图像系列显著提高GIST病变的SNR和CNR,并改善腹部DECT数据的定量与定性图像质量。

研究设计与样本

  • 对21例GIST患者(14名男性;年龄63.7±9.2岁)的45组腹部DECT数据进行重建,采用标准线性融合(M_0.6)、VMI+和传统VMI算法以10 keV为间隔从40至100 keV重建;在GIST病变和腹部转移灶进行衰减测量以计算客观SNR和CNR,并用五分法评估整体图像质量、病变轮廓、图像锐利度和图像噪声。

关键影像表现/征象

  • GIST病变和腹部转移灶的衰减测量用于计算SNR和CNR,定量参数在40 keV VMI+系列达峰值(SNR 27.8±13.0;CNR 26.3±12.7)。
  • 定性图像参数中,整体图像质量和图像锐利度在60 keV VMI+重建最高(中位数均为5,P≤0.023)。
  • 病变轮廓定性评估在40和50 keV VMI+系列达峰值(中位数均为5)。
  • 图像噪声在90和100 keV的VMI和VMI+重建中更优(中位数均为5)。

诊断标准与关键数值

  • 定量参数:40 keV VMI+的SNR 27.8±13.0、CNR 26.3±12.7,显著优于线性融合(SNR 16.8±7.3;CNR 13.6±6.9)及所有VMI系列(均P<0.001)。
  • 定性参数采用五分法评估,整体图像质量和图像锐利度在60 keV VMI+最高(中位数均为5,P≤0.023)。
  • 病变轮廓在40和50 keV VMI+最佳(中位数均为5);图像噪声在90和100 keV的VMI和VMI+最佳(中位数均为5)。

临床应用与阅片要点

  • 低keV VMI+重建(尤其40 keV)可提高GIST病变的SNR和CNR,有助于病变显示。
  • 整体图像质量和锐利度以60 keV VMI+最佳,病变轮廓以40和50 keV VMI+最佳,图像噪声以90和100 keV最佳。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to evaluate the impact of a noise-optimized virtual monoenergetic imaging (VMI+) reconstruction technique on quantitative and qualitative image analysis in patients with gastrointestinal stromal tumors (GISTs) at dual-energy computed tomography (DECT) of the abdomen.

METHODS: Forty-five DECT datasets of 21 patients (14 men; 63.7 ± 9.2 years) with GISTs were reconstructed with the standard linearly blended (M_0.6) and VMI+ and traditional virtual monoenergetic (VMI) algorithm in 10-keV increments from 40 to 100 keV. Attenuation measurements were performed in GIST lesions and abdominal metastases to calculate objective signal-to-noise (SNR) and contrast-to-noise ratios (CNR). Five-point scales were used to evaluate overall image quality, lesion delineation, image sharpness, and image noise.

RESULTS: Quantitative image parameters peaked at 40-keV VMI+ series (SNR 27.8 ± 13.0; CNR 26.3 ± 12.7), significantly superior to linearly blended (SNR 16.8 ± 7.3; CNR 13.6 ± 6.9) and all VMI series (all P < 0.001). Qualitative image parameters were highest for 60-keV VMI+ reconstructions regarding overall image quality and image sharpness (median 5, respectively; P ≤ 0.023). Qualitative assessment of lesion delineation peaked in 40 and 50-keV VMI+ series (median 5, respectively). Image noise was superior in 90 and 100-keV VMI and VMI+ reconstructions (all medians 5).

CONCLUSIONS: Low-keV VMI+ reconstructions significantly increase SNR and CNR of GISTs and improve quantitative and qualitative image quality of abdominal DECT datasets compared to traditional VMI and standard linearly blended image series.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Martin SS, Pfeifer S, Wichmann JL, et al. Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors. Abdom Radiol (NY). 2017. PMID: 27999889. doi:10.1007/s00261-016-1011-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。