文献速递泌尿生殖腹部MR

质子密度脂肪分数测量:鉴别肾上腺腺瘤与非腺瘤的可行定量生物标志物

Proton-density fat fraction measurement: A viable quantitative biomarker for differentiating adrenal adenomas from nonadenomas.
PubMed 文献 · Eur J Radiol · 2016-11-05

本研究在3.0-T MR上比较质子密度脂肪分数(PDFF)与化学位移MRI(CSI)定量肾上腺结节脂肪含量及鉴别腺瘤与非腺瘤的准确性,并辅以油-盐水体模实验。结果体模中PDFF与CSI相关性良好(R²=0.972,p<0.0001),腺瘤PDFF显著高于非腺瘤(p<0.001),PDFF鉴别腺瘤的AUC为0.98,与CSI各指标(AUC 0.93–0.95)无显著差异(p>0.05)。

要点

  • PDFF鉴别肾上腺腺瘤与非腺瘤的AUC为0.98,与CSI的SII、ALR、ASR(AUC 0.94、0.95、0.93)无显著差异。
  • 腺瘤PDFF显著高于非腺瘤(p<0.001),PDFF可有效区分两者。
  • PDFF无需复杂计算,在3T MR上提供更简便的脂肪定量技术。

核心结论

  • PDFF测量能准确估计脂肪含量以鉴别腺瘤与非腺瘤,与CSI相比避免复杂数据计算,在3T上提供更简便的技术。

研究设计与样本

  • 体模研究(油-盐水体模)比较PDFF与CSI检测和定量脂肪含量的相关性;临床连续纳入43例已知肾上腺结节患者,在3.0-T MR扫描仪上成像,测量PDFF并计算SII、ALR、ASR。

诊断标准与关键数值

  • 体模中PDFF范围为12.6%–99.1%,SII为0.72–1.23,两者相关性R²=0.972(p<0.0001);腺瘤PDFF显著高于非腺瘤(p<0.001);PDFF鉴别腺瘤与非腺瘤的AUC为0.98,SII、ALR、ASR的AUC分别为0.94、0.95、0.93,两种方法间无显著差异(p>0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aims to compare the accuracy of proton-density fat fraction (PDFF) measurements with chemical shift magnetic resonance imaging (CSI) for quantifying the fat content of adrenal nodules and for differentiating adenomas from nonadenomas.

MATERIALS AND METHODS: Oil-saline phantom measurements was performed to compare the correlation between PDFF and CSI in detecting and quantifying fat content. 43 consecutive patients who had known adrenal nodules were imaged on a 3.0-T MR scanner. PDFF was measured, and the signal intensity (SI) index (SII), SI adrenal-to-liver ratio (ALR) and SI adrenal-to-spleen ratio (ASR) of the adrenal nodules were calculated.

RESULTS: In the phantom study, PDFF ranged from 12.6% to 99.1% and the SII was between 0.72 and 1.23. There was good correlation between these two methods (R square=0.972, p<0.0001). The PDFF of adrenal adenoma was significantly increased compared with that of nonadenoma (p<0.001). PDFF was an effective tool for distinguishing adenoma from nonadenoma, with an area under the curve (AUC) of 0.98. In comparing SII, ALR and ASR the AUC was 0.94, 0.95 and 0.93, respectively. No significant difference was noted between these two methods (p>0.05).

CONCLUSION: PDFF measurements provide an accurate estimation of fat content in discriminating adenomas from nonadenomas compared with CSI, avoiding complicated data calculations and offering a simpler technique using 3T.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Meng X, Chen X, Shen Y, et al. Proton-density fat fraction measurement: A viable quantitative biomarker for differentiating adrenal adenomas from nonadenomas. Eur J Radiol. 2016. PMID: 28027736. doi:10.1016/j.ejrad.2016.11.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。