胰岛素瘤的多层CT检测:全胰腺灌注成像是否有价值
回顾性纳入70例疑诊胰岛素瘤患者,均行双期增强CT及全胰腺CT灌注检查。双期CT联合灌注的敏感度94.6%、特异度94.7%,均高于单用双期CT的88.1%和85.7%,ROC曲线下面积由0.939升至0.999;作者认为加做胰腺灌注可能提高胰岛素瘤检出。
要点
- 胰岛素瘤及载瘤区胰腺的血流量均显著高于无瘤胰腺实质(P<0.01)。
- 双期CT联合灌注较单用双期CT检出敏感度、特异度均更高(94.6% vs 88.1%;94.7% vs 85.7%)。
- 双期CT上阴性或不确定的46个肿瘤中9个(19.6%)加灌注后获正确诊断。
核心结论
- 在双期增强CT基础上加做全胰腺CT灌注,可能提高胰岛素瘤的检出。
研究设计与样本
- 回顾性研究,70例连续疑诊胰岛素瘤患者(男33例、女37例;平均年龄46岁,范围17–73岁),2011年1月至2011年12月纳入,均行双期增强CT与全胰腺CT灌注,随访至少3年;两名不知临床与手术资料的放射科医师独立阅片,先仅用双期增强CT评估,再用双期CT与灌注图像联合评估,并绘制ROC曲线比较两组图像。
诊断标准与关键数值
- 胰岛素瘤及载瘤区胰腺的平均血流量(BF)均显著高于无瘤胰腺实质(P<0.01)。单用双期CT检出胰岛素瘤的敏感度88.1%、特异度85.7%、阳性预测值91.1%、阴性预测值81.4%;双期CT联合灌注的敏感度94.6%、特异度94.7%、阳性预测值96.7%、阴性预测值91.5%;ROC曲线下面积由双期CT的0.939升至加灌注后的0.999。
临床应用与阅片要点
- 阅片时可在双期增强CT基础上加做全胰腺CT灌注并测量血流量,对双期CT上阴性或不确定的病灶结合灌注参数图重新判断(双期CT阴性的2个、不确定的7个肿瘤加灌注后正确诊断)。
局限性
- 原文为回顾性研究。
- 作者结论使用「may improve」表述,提示加做灌注可能提高检出,尚需进一步确认。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study is to investigate the role of whole-pancreas perfusion in detecting insulinomas with the use of MDCT.
MATERIALS AND METHODS: From January 2011 to December 2011, a total of 70 consecutive patients (33 men and 37 women; mean age, 46 years; range, 17-73 years) who underwent biphasic contrast-enhanced CT and whole-pancreas CT perfusion for suspected insulinomas were identified retrospectively. Patients were monitored for at least 3 years. Two radiologists who were blinded to the clinical and surgical data independently evaluated the images, first assessing only the biphasic contrast-enhanced CT images to detect tumor and assess diagnostic confidence on a 5-point scale. Next, perfusion parametric maps were evaluated and pancreatic perfusion parameters measured, and the presence of tumor was reidentified using a combination of the biphasic CT and perfusion image sets. A ROC curve was generated to compare the diagnostic accuracy of the two image sets.
RESULTS: The mean blood flow (BF) values of both the insulinomas and the insulinoma-harboring regions were statistically significantly higher (p < 0.01, for both) than the BF value of tumor-free pancreatic parenchyma. For the detection of insulinoma, biphasic CT had a sensitivity of 88.1%, a specificity of 85.7%, a positive predictive value of 91.1%, and a negative predictive value of 81.4%, whereas combined biphasic CT and perfusion had a sensitivity of 94.6%, a specificity of 94.7%, a positive predictive value of 96.7%, and a negative predictive value of 91.5%. The mean area under the ROC curve increased from 0.939 with biphasic CT to 0.999 with the addition of perfusion. Nine of 46 tumors (19.6%) for which findings were negative (n = 2) or indeterminate (n = 7) on biphasic CT were correctly diagnosed with the addition of perfusion.
CONCLUSION: The addition of pancreatic perfusion to biphasic contrast-enhanced CT may improve the detection of insulinomas.
引用
- Zhu L, Xue H, Sun H, et al. Insulinoma Detection With MDCT: Is There a Role for Whole-Pancreas Perfusion? AJR Am J Roentgenol. 2016. PMID: 27929662. doi:10.2214/AJR.16.16351