儿童脂肪肝患者肝脏硬度:剪切波弹性成像的诊断准确性与可重复性
研究纳入68例经活检证实为非酒精性脂肪性肝炎的连续儿童和青少年患者,采用超声剪切波弹性成像评估肝纤维化程度。剪切波弹性成像与肝纤维化高度相关(P < .001),诊断任何纤维化(≥F1)和显著纤维化(≥F2)的AUC分别为0.92(95%CI:0.86,0.98)和0.97(95%CI:0.95,0.99),组内相关系数为0.95(95%CI:0.90,0.97)。作者认为剪切波弹性成像能准确、可重复地检出显著肝纤维化,对轻度纤维化的准确性较低,尚需更大规模前瞻性研究确认其准确性并建立纤维化分级阈值。
要点
- 剪切波弹性成像诊断显著纤维化(≥F2)的AUC为0.97(95%CI:0.95,0.99)。
- 诊断任何纤维化(≥F1)的AUC为0.92(95%CI:0.86,0.98)。
- 组内相关系数为0.95(95%CI:0.90,0.97),提示可重复性高。
核心结论
- 剪切波弹性成像是一种准确且可重复的无创技术,能有效检出儿童非酒精性脂肪性肝病患者的显著肝纤维化,对轻度肝纤维化的准确性较低。
研究设计与样本
- 研究为连续纳入儿童和青少年患者的诊断准确性研究,样本量为68例经活检证实为非酒精性脂肪性肝炎的患者(37例男孩和31例女孩;平均年龄12.6岁±2.48;年龄范围8-17岁)。
- 采用基于超声的剪切波弹性成像系统进行检查,以组织学检查结果作为参考标准。
诊断标准与关键数值
- 剪切波弹性成像诊断任何纤维化(评分≥F1)的AUC为0.92(95%CI:0.86,0.98)。
- 剪切波弹性成像诊断显著纤维化(评分≥F2)的AUC为0.97(95%CI:0.95,0.99)。
- 绝对一致性组内相关系数为0.95(95%CI:0.90,0.97)。
临床应用与阅片要点
- 作者认为剪切波弹性成像能准确、可重复地检出显著肝纤维化,对轻度肝纤维化的准确性较低。
- 作者提出尚需更大规模前瞻性研究确认剪切波弹性成像的准确性,并与其他无创方法比较或联合使用以建立纤维化分级阈值。
局限性
- 作者指出尚需更大规模前瞻性研究确认剪切波弹性成像的准确性并建立纤维化分级阈值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To evaluate the diagnostic accuracy of shear-wave elastography (SWE) in identifying different degrees of fibrosis in a cohort of consecutive children and adolescents with nonalcoholic steatohepatitis (NASH). Materials and Methods Consecutive pediatric patients scheduled to undergo liver biopsy were studied with an ultrasonography-based SWE system. Elastography was performed in 68 of 69 patients with biopsy-proved NASH (37 boys and 31 girls; mean age, 12.6 years ± 2.48; age range, 8-17 years). The correlations among laboratory findings, liver stiffness, and fibrosis score were analyzed, and the area under the receiver operating characteristic curve (AUC) was used to assess the presence of any fibrosis (score ≥F1) or significant fibrosis (score ≥F2). Findings from histologic examination were used as the standard of reference. Results SWE showed a very high correlation with liver fibrosis (P < .001) at univariate and multivariate analyses. The AUCs for the association of any and significant fibrosis were 0.92 (95% confidence interval [CI]: 0.86, 0.98) and 0.97 (95% CI: 0.95, 0.99), respectively. The intraclass correlation coefficient for absolute agreement was 0.95 (95% CI: 0.90, 0.97). Conclusion SWE is an accurate and reproducible noninvasive technique that efficiently depicts the presence of significant liver fibrosis and, less accurately, mild liver fibrosis in pediatric patients with nonalcoholic fatty liver disease. Larger clinical prospective studies are warranted to confirm SWE accuracy and establish threshold values for fibrosis grading in comparison or in combination with other noninvasive methods. © RSNA, 2016.
引用
- Garcovich M, Veraldi S, Di Stasio E, et al. Liver Stiffness in Pediatric Patients with Fatty Liver Disease: Diagnostic Accuracy and Reproducibility of Shear-Wave Elastography. Radiology. 2016. PMID: 27982761. doi:10.1148/radiol.2016161002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。