文献速递腹部技术与安全CT

固定容积与基于体重给药方案对腹部CT碘对比剂费用与用量影响的效应

Effect of Fixed-Volume and Weight-Based Dosing Regimens on the Cost and Volume of Administered Iodinated Contrast Material at Abdominal CT.
PubMed 文献 · J Am Coll Radiol · 2016-12-21

该回顾性队列研究纳入2014至2015年6737例接受对比增强腹盆部CT的受试者,比较26种文献支持的容积与体重给药策略与本院固定容积方案(常规125 mL 300 mgI/mL,多期125 mL 370 mgI/mL)在费用与对比剂利用上的差异。转换为低容积高浓度对比剂对费用影响最大,固定容积100 mL 370 mgI/mL策略在常规CT保持碘剂量(37,500 vs 37,000 mgI)的同时可实现人群层面节省132,577美元;所有体重基碘含量给药策略均预测可节省费用。结论认为采用体重给药策略并降低最大给药容积可在腹盆部CT实现大幅费用与材料节省。

要点

  • 常规CT占91%(6,127/6,737),多数受试者接受常规CT检查。
  • 固定容积100 mL 370 mgI/mL策略在常规CT保持碘剂量(37,500 vs 37,000 mgI)并节省132,577美元。
  • 所有体重基碘含量给药策略(最大容积125 mL)均预测可节省费用。

核心结论

  • 采用基于体重的给药策略并降低最大给药容积可在腹盆部CT实现大幅费用与材料节省。

研究设计与样本

  • HIPAA合规、机构审查委员会豁免的回顾性队列研究,纳入2014至2015年6,737例接受对比增强腹盆部CT的受试者;比较26种文献支持的容积与体重给药策略与本院固定容积策略(常规CT 125 mL 300 mgI/mL,多期CT 125 mL 370 mgI/mL,单能120 kVp),并计算预测的人群与个体层面费用及对比剂利用效应,进行敏感性分析。

诊断标准与关键数值

  • 固定容积100 mL 370 mgI/mL策略在常规CT保持碘剂量(37,500 vs 37,000 mgI),人群层面节省132,577美元。
  • 所有体重基碘含量给药策略(mgI/kg)且最大对比剂容积为125 mL,预测总体研究人群平均节省4,053至116,076美元/策略,每例患者节省1至17美元/策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the magnitude of subject-level and population-level cost savings that could be realized by moving from fixed-volume low-osmolality iodinated contrast material administration to an effective weight-based dosing regimen for contrast-enhanced abdominopelvic CT.

METHODS: HIPAA-compliant, institutional review board-exempt retrospective cohort study of 6,737 subjects undergoing contrast-enhanced abdominopelvic CT from 2014 to 2015. Subject height, weight, lean body weight (LBW), and body surface area (BSA) were determined. Twenty-six volume- and weight-based dosing strategies with literature support were compared with a fixed-volume strategy used at the study institution: 125 mL 300 mgI/mL for routine CT, 125 mL 370 mgI/mL for multiphasic CT (single-energy, 120 kVp). The predicted population- and subject-level effects on cost and contrast material utilization were calculated for each strategy and sensitivity analyses were performed.

RESULTS: Most subjects underwent routine CT (91% [6,127/6,737]). Converting to lesser-volume higher-concentration contrast material had the greatest effect on cost; a fixed-volume 100 mL 370 mgI/mL strategy resulted in $132,577 in population-level savings with preserved iodine dose at routine CT (37,500 versus 37,000 mgI). All weight-based iodine-content dosing strategies (mgI/kg) with the same maximum contrast material volume (125 mL) were predicted to contribute mean savings compared with the existing fixed-volume algorithm ($4,053-$116,076/strategy in the overall study population, $1-$17/strategy per patient). Similar trends were observed in all sensitivity analyses.

CONCLUSIONS: Large cost and material savings can be realized at abdominopelvic CT by adopting a weight-based dosing strategy and lowering the maximum volume of administered contrast material.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Davenport MS, Parikh KR, Mayo-Smith WW, et al. Effect of Fixed-Volume and Weight-Based Dosing Regimens on the Cost and Volume of Administered Iodinated Contrast Material at Abdominal CT. J Am Coll Radiol. 2016. PMID: 28017270. doi:10.1016/j.jacr.2016.09.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。