18F-FDG PET/CT 延迟显像联合强制利尿重新评估腹盆腔恶性肿瘤
回顾性分析46例腹盆腔标准18F-FDG PET/CT显示不确定或可疑病灶的患者,在静脉注射20 mg 呋塞米并额外饮水500 mL后行延迟腹盆腔显像。延迟显像利尿后尿液放射性清除良好,所有病例高代谢病灶均得以清晰显示并精确定位,灵敏度94.4%(34/36)、特异度8/10、准确率91.3%(42/46);8/46(17.4%)患者仅延迟显像发现周围侵犯或区域转移灶。
要点
- 标准PET/CT腹盆腔病灶被尿液放射性掩盖或尿路旁不确定摄取时,可加做利尿后延迟显像。
- 延迟显像利尿后尿液示踪剂清除良好,高代谢病灶可清晰显示并精确定位。
- 46例中8例(17.4%)仅延迟显像发现周围侵犯或区域转移,包括2例妇科和6例直肠恶性肿瘤。
核心结论
- 利尿和口服水化后的延迟18F-FDG PET/CT显像可提高腹盆腔恶性肿瘤的检测。
研究设计与样本
- 回顾性研究,纳入46例患者(泌尿系统疾病17例、妇科肿瘤9例、结直肠恶性肿瘤18例、原发灶不明癌2例),标准18F-FDG PET/CT腹盆腔显示不确定或可疑病灶后,静脉给予20 mg 呋塞米并额外饮水500 mL行延迟腹盆腔显像,与病理或临床随访(>6个月)对照。
关键影像表现/征象
- 初始PET/CT中病灶的葡萄糖代谢特征被放射性尿液掩盖,或尿路附近出现不确定的18F-FDG摄取灶;利尿后PET/CT显示尿液示踪剂清除良好,所有病例高代谢病灶均可清晰检测并精确定位,尿路中排泄的18F-FDG潜在滞留所致的可疑活动灶被排除。
诊断标准与关键数值
- 延迟显像诊断腹盆腔恶性肿瘤的灵敏度94.4%(34/36)、特异度8/10、准确率91.3%(42/46)。
临床应用与阅片要点
- 对标准18F-FDG PET/CT腹盆腔显示不确定或可疑病灶的患者,可行静脉呋塞米20 mg加饮水500 mL后的延迟腹盆腔显像,以区分尿液放射性掩盖或尿路滞留所致假灶并检出周围侵犯或区域转移。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this retrospective study was to evaluate the role of delayed images after forced diuresis coupled with oral hydration in abdominopelvic 18F-FDG PET/CT.
MATERIALS AND METHODS: Forty-six patients consisting of 17 urological diseases, 9 gynecological tumors, 18 colorectal malignancies, and 2 cancers of unknown primary site were retrospectively analyzed. All patients who presented with indeterminate or equivocal abdominopelvic foci on standard 18F-FDG PET/CT underwent a delayed abdominopelvic imaging after administration of 20 mg furosemide intravenously and extra water intake of 500 mL. PET/CT images before and after furosemide were compared with each other and their findings correlated with pathology or clinical follow-up (>6 months).
RESULTS: On initial PET/CT, the glucose metabolism characters of lesions were disguised by radioactive urine, or some undetermined 18F-FDG accumulating foci near the urinary tract appeared. While postdiuretic PET/CT demonstrated an excellent urinary tracer washout, and hypermetabolic lesions could be clearly detected and precisely localized in all cases. On the other hand, the suspected active foci caused by potential stagnation of excreted 18F-FDG in urinary tract were eliminated. The sensitivity, specificity, and accuracy were 94.4% (34/36), 8/10, 91.3% (42/46), respectively. Furthermore, the additional lesions with surrounding invasion or locoregional metastasis were discovered in 8 of 46 (17.4%) patients only by the delayed images, including 2 gynecological and 6 rectal malignancies.
CONCLUSION: Detection of abdominopelvic malignancies can be improved using delayed 18F-FDG PET/CT images after a diuretic and oral hydration.
引用
- Wang HC, Wang ZM, Wang YB, et al. 18F-FDG PET/CT delayed images with forced diuresis for revaluating abdominopelvic malignancies. Abdom Radiol (NY). 2017. PMID: 28028557. doi:10.1007/s00261-016-1030-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。