双源冠状动脉CTA中运动映射技术下的RIF重建显著减少致心律失常伪影
本研究对23例疑似冠心病或拟行经导管主动脉瓣置换术患者的CT数据集,比较BS、BD、RIF与RIMM四种重建技术的诊断质量,由两名放射科医师采用15节段AHA模型和六级Likert量表盲法评估。RIMM在345个冠状动脉节段中66%(228个)达到可靠诊断质量,显著优于RIF(P=0.002)和BS/BD(P<0.001)。作者认为RIMM可消除伪影,有助于快速可靠评估冠状动脉树,避免进一步有创诊断。
要点
- RIMM重建在345个冠状动脉节段中228个(66%)达到可靠诊断质量
- RIMM诊断质量显著优于RIF(P=0.002)及BS/BD重建(P<0.001)
- RIMM在右冠状动脉方面评分优于RIF重建(P=0.041)
核心结论
- 作者认为RIMM技术有效,在最差CT图像上大幅消除伪影,使放射科医师能清晰显示这些节段,有助于快速可靠评估冠状动脉树,避免进一步有创诊断。
研究设计与样本
- 对23例疑似冠心病或拟行经导管主动脉瓣置换术患者的CT数据集进行手动选取,每例用BS、BD、RIF和RIMM四种技术重建,两名放射科医师盲法采用15节段AHA模型和六级Likert量表评估冠状动脉树。
关键影像表现/征象
- 常规BestSystole(BS)和BestDiastole(BD)重建在心律失常患者中常出现伪影,妨碍冠状动脉树的判读
- RIMM重建在345个分析节段中228个(66%)显示可靠诊断质量
- RIMM在各冠状动脉节段、各血管及每位患者层面的评分显著优于常规BS/BD重建(P=0.003)
- RIMM在右冠状动脉方面评分优于RIF重建(P=0.041)
诊断标准与关键数值
- 采用15节段美国心脏协会(AHA)模型评估冠状动脉树
- 采用六级Likert量表评估图像诊断质量
- RIMM可靠诊断质量节段228/345(66%),优于RIF(P=0.002)和BS/BD(P<0.001)
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Particularly for patients with heart arrhythmias, conventional BestSystole (BS) and BestDiastole (BD) reconstruction techniques in computed tomography (CT) frequently show artifacts that hinder the readability of the coronary tree. To address this problem, this paper presents an alternative reconstruction method that combines the technique "reconstructions with identical filling" (RIF) with motion mapping: This new technique is called "RIF in motion mapping" (RIMM). This study compares the diagnostic quality of images generated with RIMM to that of the other reconstruction techniques.
MATERIALS AND METHODS: Having shown major artifacts in standard reconstructions, the CT datasets of 23 patients with suspected coronary artery disease or prior to transcatheter aortic valve replacement were selected manually. Each dataset was evaluated with four reconstruction techniques: BS, BD, RIF, and RIMM. Two radiologists, blinded to the applied reconstruction type, then evaluated the entire coronary tree of each sample using the 15-segment American Heart Association model and the six-grade Likert scale.
RESULTS: Of the 345 analyzed coronary segments, the RIMM technique showed a significant number of images with reliable diagnostic quality (n = 228, 66%) as compared to RIF (P = 0.002) and BS/BD reconstructions (P < 0.001). Per coronary segment, vessel, and patient, the RIMM technique scored significantly better than the conventional BS/BD reconstructions (P = 0.003) and better than the RIF reconstructions with regard to the right coronary artery (P = 0.041).
CONCLUSIONS: This new technique works: Using RIMM on the worst CT images substantially erased many of these artifacts, thereby enabling the radiologists to clearly visualize these segments. As RIMM considerably eliminates artifacts, this new CT reconstruction technique can help make a fast reliable evaluation of a patient's coronary tree. Thus, this enhanced visualization of cardiac images by RIMM avoids the need for further invasive diagnostic procedures.
引用
- Reinartz SD, Winkler M, Diefenbach SB, et al. Reconstructions Using RIF in Motion Mapping Technique Have Substantially Less Arrhythmogenic Artifacts in Dual-source Coronary CTA. Acad Radiol. 2016. PMID: 28010914. doi:10.1016/j.acra.2016.09.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。