左房应变用于左室舒张功能不全的分级
本研究为回顾性推导与验证队列研究,纳入左室射血分数保留患者229例,用二维斑点追踪测量左房峰值应变,以美国超声心动图学会指南为参考标准,推导并验证左房应变分级舒张功能不全(0至3级)的阈值。推导队列中不同舒张功能不全组左房应变逐步降低,三个阈值曲线下面积0.86至0.91;验证队列中8%患者标准 criteria 无法确定分级,而左房应变均可测量,诊断准确率最高达95%。
要点
- 左房峰值应变随舒张功能不全加重而逐步降低,可用于分级。
- 推导出3个左房应变阈值对应舒张功能不全0至3级,曲线下面积0.86至0.91。
- 验证队列中左房应变诊断准确率最高达95%,标准 criteria 无法分级者占8%。
核心结论
- 左房应变测量可行,能准确分级舒张功能不全,因其随严重程度逐步变化,可能成为未来临床实践中舒张功能评估的有用工具。
研究设计与样本
- 回顾性推导与验证队列研究,纳入左室射血分数保留患者229例(推导队列n=90,验证队列n=139),采用二维斑点追踪测量左房峰值应变,以美国超声心动图学会指南为参考标准。
诊断标准与关键数值
- 推导队列受试者工作特征分析得出3个左房应变阈值用于舒张功能不全分级,曲线下面积0.86至0.91;验证队列中左房应变阈值诊断准确率最高达95%。
临床应用与阅片要点
- 左房峰值应变可作为单参数用于舒张功能不全分级,在标准 criteria 无法确定分级时仍可测量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study sought to observe the relationship between left atrial (LA) strain and left ventricular diastolic function and determine whether LA strain could be used to detect diastolic dysfunction (DD) and classify its degree when present.
BACKGROUND: The assessment of diastolic function is complex and multiparametric because most conventional parameters do not follow the progression of DD. Strain imaging is an emerging index of LA function, with recent data demonstrating that LA strain is diminished in diastolic heart failure. However, LA strain is not part of the standard assessment of diastolic function. We hypothesized that LA strain decreases with worsening DD in a stepwise fashion and could thus be useful in evaluating DD.
METHODS: We performed a retrospective derivation and validation cohort study to derive and test LA strain thresholds for DD grades (0 to 3) in patients with preserved left ventricular ejection fraction (N = 229). Two-dimensional speckle tracking was used to measure peak LA strain, which was applied as a single parameter to classify DD. American Society of Echocardiography guidelines were used as the reference standard.
RESULTS: In the derivation cohort (n = 90), peak LA strain was significantly different between DD groups, with gradual decreases seen with worsening DD. Receiver-operating characteristic analysis resulted in 3 distinct LA strain thresholds for categorization of DD grades, with good to excellent diagnostic utility (area under the curve: 0.86 to 0.91). In an independent validation group (n = 139) with a spectrum of diastolic function, 11 patients (8%) had indeterminate DD grades using standard criteria, whereas LA strain was measured in all patients and its cutoffs resulted in diagnostic accuracy up to 95%.
CONCLUSIONS: LA strain measurements are feasible and allow accurate categorization of DD, because unlike the traditional parameters, it changes progressively with severity of DD. LA strain may become a useful tool for diastolic assessment in future clinical practice.
引用
- Singh A, Addetia K, Maffessanti F, et al. LA Strain for Categorization of LV Diastolic Dysfunction. JACC Cardiovasc Imaging. 2016. PMID: 28017389. doi:10.1016/j.jcmg.2016.08.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。