文献速递心血管MRUS

多参数心血管磁共振定量三尖瓣反流:与超声心动图的比较

Multi-parametric quantification of tricuspid regurgitation using cardiovascular magnetic resonance: A comparison to echocardiography.
PubMed 文献 · Eur J Radiol · 2016-11-23

研究61例三尖瓣反流患者,在24小时内完成心血管磁共振与超声心动图检查,以缩流颈宽度将反流分为重度(20例)与中度或轻度(41例)。在短轴稳态自由进动序列上测量反流束面积和归一化信号强度,反流束面积随严重程度增加而增大,归一化信号强度降低,ROC分析显示推导组AUC值高、测试组准确性良好。结论认为短轴心血管磁共振可定量三尖瓣反流,与超声心动图一致,且无需额外专用成像序列。

要点

  • 短轴稳态自由进动序列上右心房内信号丢失区可测量三尖瓣反流束,61例中51例可测。
  • 重度反流组反流束面积15±14至38±20mm²、归一化信号强度57±27至23±11。
  • ROC分析示推导组AUC值高,测试组区分反流程度准确性良好。

核心结论

  • 短轴心血管磁共振图像可定量三尖瓣反流,与超声心动图结果一致,且避免了额外的图像采集。

研究设计与样本

  • 研究纳入61例三尖瓣反流患者,在24小时内行心血管磁共振与超声心动图检查;以缩流颈宽度为参考标准分为重度20例、中度或轻度41例;在显示最大反流束面积的平面和帧上测量反流束面积和归一化信号强度;在21/61例中行ROC分析确定区分反流程度的诊断准确性,并在其余40例中独立测试最佳截断值。

关键影像表现/征象

  • 在短轴稳态自由进动图像上,51/61例可见可测量的信号丢失区,代表三尖瓣反流束。
  • 其余10例中9例超声心动图显示为轻度三尖瓣反流。
  • 随着三尖瓣反流严重程度增加,反流束面积显著增大(15±14至38±20mm²)。
  • 随着三尖瓣反流严重程度增加,归一化信号强度降低(57±27至23±11)。

诊断标准与关键数值

  • 以缩流颈宽度为参考标准,将三尖瓣反流分为重度(N=20)和中度或轻度(N=41)。
  • ROC分析在推导组(21/61例)显示高AUC值,在测试组(40例)显示良好准确性。
  • 最佳截断值在推导组确定,并在其余40例中独立测试。

临床应用与阅片要点

  • 可在短轴稳态自由进动序列上测量右心房内三尖瓣反流束面积和归一化信号强度,用于评估反流严重程度。
  • 该方法无需额外的速度编码专用成像序列即可定量三尖瓣反流。
  • 51/61例可测得反流束信号丢失区,10例不可测者中9例超声心动图为轻度反流。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Velocity-encoding is used to quantify tricuspid regurgitation (TR) by cardiovascular magnetic resonance (CMR), but requires additional dedicated imaging. We hypothesized that size and signal intensity (SI) of the cross-sectional TR jet area in the right atrium in short-axis steady-state free-precession images could be used to assess TR severity.

METHODS: We studied 61 patients with TR, who underwent CMR and echocardiography within 24h. TR severity was determined by vena contracta: severe (N=20), moderate or mild (N=41). CMR TR jet area and normalized SI were measured in the plane and frame that depicted maximum area. ROC analysis was performed in 21/61 patients to determine diagnostic accuracy of differentiating degrees of TR. Optimal cutoffs were independently tested in the remaining 40 patients.

RESULTS: Measurable regions of signal loss depicting TR jets were noted in 51/61 patients, while 9/10 remaining patients had mild TR by echocardiography. With increasing TR severity, jet area significantly increased (15±14 to 38±20mm2), while normalized SI decreased (57±27 to 23±11). ROC analysis showed high AUC values in the derivation group and good accuracy in the test group.

CONCLUSION: TR can be quantified from short-axis CMR images in agreement with echocardiography, while circumventing additional image acquisition.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Medvedofsky D, León Jiménez J, Addetia K, et al. Multi-parametric quantification of tricuspid regurgitation using cardiovascular magnetic resonance: A comparison to echocardiography. Eur J Radiol. 2016. PMID: 28027750. doi:10.1016/j.ejrad.2016.11.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。