对比剂时间-强化曲线分析优化CT肺动脉造影
前瞻性纳入100例连续行增强胸部CT的患者,每2秒采集15幅低辐射监测图像,分析肺动脉强化峰值与达峰时间,比较固定延迟与循环调整延迟的强化质量;平均峰值强化431.4±65.2 HU,平均达峰时间22.4±3.1秒,固定延迟19秒及以150 HU团注跟踪阈值联合10秒诊断延迟的循环调整方案强化质量最高。
要点
- 肺动脉平均峰值强化431.4±65.2 HU,平均达峰时间22.4±3.1秒,峰值多出现在20秒注射结束后。
- 候选固定延迟11–27秒中,19秒的强化质量最高。
- 循环调整延迟中,150 HU团注跟踪阈值联合10秒诊断延迟的强化质量最高。
核心结论
- 肺动脉峰值强化平均出现在20秒对比剂注射结束后;固定扫描延迟19秒或以150 HU为团注跟踪阈值联合10秒诊断延迟的循环调整方案似乎最优。
研究设计与样本
- 前瞻性研究连续纳入100例转诊行增强胸部CT的患者,注射370 mg碘/mL对比剂1 mL/kg体重、20秒注射完毕,注射开始后5秒起每2秒采集15幅低辐射监测图像,测量肺动脉对比剂时间-强化数据。
关键影像表现/征象
- 肺动脉平均峰值强化为431.4±65.2 HU(范围263.8–575.3 HU)。
- 平均达峰时间为22.4±3.1秒(范围11–27秒)。
诊断标准与关键数值
- 计算达峰时间与峰值幅度以及达到50、100、150、200、250 HU五个强化阈值的时间。
- 候选固定延迟范围11–27秒,其中19秒显示最高强化质量。
- 循环调整延迟中,150 HU团注跟踪阈值联合10秒诊断延迟的组合强化质量最高。
临床应用与阅片要点
- 可参考固定扫描延迟19秒或以150 HU为团注跟踪阈值联合10秒诊断延迟的循环调整方案来优化肺动脉强化质量。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To assess enhancement profiles of the pulmonary artery (PA) and determine optimal scan timing in PA computed tomography (CT) angiography.
MATERIALS AND METHODS: One hundred consecutive patients referred for contrast-enhanced chest CT were prospectively studied. Fifteen low-radiation monitoring images were acquired at 2-second intervals, 5 seconds after the start of an injection of 370 mg iodine/I contrast medium for 1 ml/kg of body weight injected over 20 seconds. Contrast time-enhancement data were measured over the PA. The time and magnitude of peak as well as times to five different enhancement thresholds (50, 100, 150, 200, 250 HU) were calculated. A set of candidate fixed and circulation-adjusted scan delays were analysed and compared in terms of the quality of contrast enhancement over the 4-second diagnostic scan duration.
RESULTS: The mean degree of peak PA enhancements was 431.4±65.2HU (range, 263.8-575.3HU). The mean time to peak enhancement was 22.4±3.1 seconds (range, 11-27 seconds). From potential fixed delays ranging 11-27 seconds, 19 seconds showed the highest enhancement quality. For the circulation-adjusted delays, the combination of 150 HU bolus-track threshold with diagnostic delay of 10 seconds had the highest enhancement quality.
CONCLUSION: Peak enhancement of PA occurred, on average, right after completion of contrast injection for 20 seconds. The fixed scan delay of 19 seconds or circulation-adjusted delay with the bolus-threshold of 150 HU and diagnostic delay of 10 seconds appear optimal.
引用
- Zhu J, Wang Z, Kim Y, et al. Analysis of contrast time-enhancement curves to optimise CT pulmonary angiography. Clin Radiol. 2016. PMID: 28027777. doi:10.1016/j.crad.2016.11.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。